USER MANUAL – Mantis™ II 433.92MHz Reader
13
U
WARNING – Computer administrative privileges are recommended
when using the network-enabled Reader programmer utility. In the
event of IP resolution conflicts, the utility will attempt to modify the
Address Resolution Protocol (ARP) table. On some systems this can
only be achieved with sufficient privileges.
Reader Settings
(R)eader # R
R - Select a new Reader to program.
• Reads and displays a Reader’s saved calibration and settings from its
configuration file (SSI_info\AXnnnnnn.txt where AXnnnnnn is the
serial number). Any undefined settings will remain blank.
• Errors are displayed if the info file is missing or contains bad
calibration data.
• The Reader # is the s/n (serial number) on the silver label on the
underside of the Reader. When entering this number ignore the space
between the two sets of 4 numbers and input it as a single 8-digit
alpha-numeric serial number.
(U)B processor FW U
U – Choose firmware revision for the network processor.
• Prints list of available files.
• Type the desired filename (case-sensitive).
• An error message is displayed if the firmware file cannot be found.
(D)A processor SW D
D – Choose firmware revision for the DSP processor.
• Prints list of available files.
• Type the desired filename (case-sensitive).
• An error message is displayed if the firmware file cannot be found.
Calibration (loaded from reader in upload process)
Reader calibration data.
• This field only displays the calibration data for the Reader at the time
of the upload process, when this information is retrieved from the
Reader. This field is informational only and cannot be modified.