Technical data

Page 11
Page __________ of __________
Options for INFRA-REZ
®
HEATER Model TR
Options
Continued on following page
Full Rate Input at
Elevations Over 2000 FT.
INFRA-REZ
®
Model TR heaters equipped for high altitude op-
eration will provide full rate input which means no loss in fuel
efficiency or heat. High altitude operation is available for use
with either natural or propane gas.
Just by selecting the desired high altitude option, the heater
will be shipped, factory-equipped for full rate operation at that
elevation.
High Altitude Kits - Models TR 50, 75, 100, 175, and 200
may be converted in the field for high altitude operation by
installing a high altitude conversion kit.
Factory Built (All Sizes)
Dual Venting
A unique design (patent pending) allows dual venting of two
INFRA-REZ
®
Model TR heaters. The concentric design of
the vent allows each of the two heaters to be safely operated
totally independent of the other. Heaters vented through the
optional dual vent do not have to match in capacity, length, or
configuration and may be controlled by the same or different
thermostats.
Minimum
Length
Maximum
Length
Alternative
Length(s) Using 1.5
m (5-ft) Tube(s)
Size Meters Feet Meters Feet Meters Feet
50
6.1 20 9.1 30 7.6 25
75
6.1 20 12.2 40 7.6 or 10.7 25 or 35
100
9.1 30 15.2 50 10.7 or 13.7 35 or 45
125
12.2 40 15.2 50 13.7 45
150
15.2 50 18.3 60 16.8 55
175
15.2 50 21.3 70 16.8 or 19.8 55 or 65
200
15.2 50 21.3 70 16.8 or 19.8 55 or 65
REZNOR
4 / 100 mm
VENT CAP
REZNOR
6 / 150 mm
VENT CAP
4 / 100 mm
VENT PIPE
(FIELD SUPPLIED)
6 / 150 mm
VENT PIPE
(FIELD SUPPLIED)
REZNOR
CONCENTRIC
ADAPTER
ASSEMBLY
UNIT #2
FLUE GAS
DIRECTION
CUTAWAY VIEW
UNIT #1
FLUE GAS
DIRECTION
ELEVATION FULL BTUH RATE
OPERATION
U.S.A. ELEVATION
Option Code
A
Meters Feet
A
STD 0 - 600 0 - 2,000
OPT. AB2 601 - 900 2,001 - 3,000
OPT. AB3 901 - 1,200 3,001 - 4,000
OPT. AB4 1,201 - 1,500 4,001 - 5,000
B
Not available for TR-200.
OPT. AB5 1,501 - 1,800 5,001 - 6,000
OPT. AB6
B
1,801 - 2,100 6,001 - 7,000
OPT. AB7
B
2,101 - 2,400 7,001 - 8,000
Installations above
2,000 feet in Canada,
use Option AB3.
or . . . Field Converted (TR50/TR75/TR100/TR175/TR200)
THIS APPLIANCE HAS BEEN CONVERTED AT THE TIME OF INSTAL-
LATION FOR HIGH ALTITUDE USE WITH KIT NO. 120 360
BY ______________________________________________ WHO
ACCEPTS THE RESPONSIBILITY FOR THE CORRECTNESS OF THIS
CONVERSION.
MODEL TR 100 FOR USE AT 2001 - 4000 FT., 611-1219 METERS OF
ALTITUDE ORIFICE SIZE #10 DRILL
NOTE: Sizes 125 and 150 are not designed for field conversion.
5-FT Heat Exchanger
Five-foot heat exchanger tubes are available to customize a
tubular system to “fit” the area needing heat. Refer to Form
RGM-607 section on Optional 5 ft. Heat Exchanger Tubes for
information and restrictions.
Overall minimum and maximum lengths by size do not change:
Order the shorter length system plus the needed quantity of
5-ft. heat exchanger tubes (Option UA-1); or, see the “Order-
ing Methods” section of this catalog for information on how to
order and stock the components to build a modular system.
Whether ordered as an option or a part, the 5-ft. tube, its
reflector, and hardware will arrive in a separately-marked car-
ton.
Note: Do not install a 5-ft. tube in place of a 10-ft tail pipe. All systems must
have a 10-ft tail pipe.