Specifications

21
Figure 12. Heater Assembly: Model Linear 100-S50, 125-S50, 150-S50, 170-S50, and 200-S50
G
F
G GH
S F
* HT COUPLER
ON MODELS 38,
45, 50 & 60
BURNER
END
CAPS
(OPTIONAL)
6"
4"
51'6½" NOMINAL OVERALL ASSEMBLED LENGTH
END
CAPS
(OPTIONAL)
DISTANCE BETWEEN
SUSPENSION
POINTS NOT TO
EXCEED 12'
10' 3" REFLECTORS
TYPICAL OF 5
G
S
BURNER INSERT
SEE DETAIL
6" REFLECTOR
OVERLAP
FIRST SUSPENSION POINT TUBE STRAP
DETAIL
TUBE & REFLECTOR SUSPENSION BRACKET
DETAIL
DETAIL
SLIDING REFLECTOR BRACKET
DETAIL
FIXED REFLECTOR BRACKET
REFLECTOR
TUBE
STRAP
RADIANT
TUBE
2 x SCREWS TIGHTEN TO
FIX REFLECTOR
2 x SCREWS MIN 1/8" GAP TO
ALLOW REFLECTOR TO SLIDE
SUPPLIED
NUT &
BOLT
C
L
2" MINIMUM
REFLECTOR OVERLAP BURNER INSERT DETAIL PT. NO. 270489
NOTE: FOR MODEL 30 NAT GAS ONLY
H G
SF
STANDARD 4" COUPLER
* HIGH TEMP 4" COUPLER
6" REFLECTOR
OVERLAP
COUPLER
(HT COUPLER
MODELS 50 & 60)
G
F
3" REFLECTOR
OVERLAP
3" REFLECTOR
OVERLAP
NAT GAS
BTU/HR
LP GAS
BTU/HR
MODEL NUMBER
30-S50
100,000 100,000
*38-S50
123,500 125,000
*45-S50
150,000 150,000
*50-S50
169,000 169,000
*60-S50
200,000
n/a
TUBE
STRAP
RADIANT
TUBE
SUPPLIED
NUT & BOLT
SUSPENSION
BRACKET
REFLECTOR
"A"
VIEW ON "A"
100-S50
125-S50
150-S50
Burner Rating
170-S50
200-S50