Parts Manuals Manual

Form P-ADF, P/N 270068 R1, Page 4
CODE 2 -
Relay and
Socket
Base
Time Delay
Relay
(Freezestat),
P/N 89661
CODE 1A, Replacement
Light for Circuit Analyzer
Board - P/N 125189
CODE 1B, Replacement
Relay for Board, P/N
151271
CODE 1 - Circuit Analyzer
Board, P/N 151263
CODE 7 -
Manual
Reset, High
Temperature
Limit
CODES 8 and 9 -
P/N 126170, High
Ambient Cutoff
and Freezestat
Grommet Clamp,
P/N 131993;
Cable Clamp,
P/N 132065
CODE 4 - Starter Relay
for Single and 2-Speed
Starters (Options AN10
and AN12), P/N 110656
CODE 6 -
Automatic
Reset Limit
Control
Limit Switch Shield,
P/N 12229
CODE 21 - 8 Amp
Fuse, P/N 201773
CODE 22 -
Terminal Block,
P/N 144972
Used in both the Electrical
Compartment and the
Remote Console
CODE 23 -
Mounting Adapter
for Terminal
Block, P/N 144973
CODE 20 -
Fuseholder,
P/N 60241
Sampling Tube, P/N 259069
CODE 16 - DPDT System
Switch, P/N 101900 (winter/
off/summer)
CODE 15 -
Door Switch,
P/N 124253,
Option BX1
CODE 17 -
SPDT
Switch,
P/N 101901
CODE 18 -
Photoelectric Smoke
Detector, P/N 159553
(Same as Option SA1)
CODE 14 -
Dirty Filter
Pressure
Switch,
P/N 105507
CODE 13 -
Convenience
Outlet
Receptacle,
P/N 96912
CODE 24 -
Transformers
Replace
pressure switch
P/N 86986 with
Kit P/N 193806.
CODE 10 -
Firestat,
P/N 42782
CODE 11 - Low Air Pressure
Switch, .25, P/N 203932
(units mfgd beginning 9/03)
CODE 12 - High Air
Pressure Switch, .75,
P/N 203933 (units
mfgd beginning 9/03)
Replace pressure switch P/N 86987
with Kit P/N 193807.
CODE 5 - Energy
Cutoff Device,
P/N 82414
CODE Description Location (page 3) P/N
13 Bushing and Insect Screen for Sensing Probes (not illustrated) 96794
14 Convenience Outlet Receptacle, Hubbell #GF5352-1 Control Compartment 96912
15 Dirty Filter Pressure Switch, Tri-Delta #AP4434, set at .3" w.c. (remote console option) Electrical Compartment 105507
16 Door Switch, Honeywell Micro-Switch #LLSNIA-3P (Option BX1) Space (on overhead door) 124253
17 DPDT System Switch, Summer/Off/Winter Space (Remote Console) 101900
18 SPDT Toggle Switch, on/on Space (Remote Console) 101901
19 Photoelectric Air Duct Smoke Detector, D4120 (Option SA1) Ductwork 159553
20 Fuseholder Electrical Compartment 60241
21 Fuse, 8 Amp, Fusetron Electrical Compartment 201773
22 Terminal Block, #KT3
Electrical Compartment &
Remote Console
144972
23 Terminal Block Mounting Adapter, KAD 144973
24 Transformer (See P/N's below.) Electrical Compartment
40VA
200-
500 VA
Volts In Volts Out VA Manufacturer's No.
Reznor
®
P/N
120/240 24 250
TB1-81146 (used w/hot surface
ignition)
38634
120 24 40
Basler #BE141650-WAA (Used
with spark igntion) (2 required to
replace P/N 61806)
103055
120 24 500 Hevi-Duty T500E 159842
208/240 24 40
Basler #BE21539001 (2 required
to replace P/N 61807)
103497
208/230/460 24 500 Hevi-Duty T500CK 159843
208/230/460/575 110 275 C0275KAU E5E 105202
208 110 500 Hevi-Duty #2227003T00 86998
208 24 200 Hevi-Duty #2223034T00 39094
208/240/480/575 24 200 C0200KAT 39095
230/460 110 500 Hevi-Duty #2227001T00 86997
208/240/ 460/575
Dual Windings
120 & 24
400
NSC-24H9-0908 200-400VA1P
(used on RDF w/REC)
124002
460 24 40
Basler #BE23975001 (2 required
to replace P/N 61808)
103498
CODE 3
Time Delay
Relay, 24V
coil, P/N
89254