Parts Manuals Manual
Form P-ADF, P/N 270068 R1, Page 3
Model ADF/ADFH
System Congurations
(Sizes 300 and 500 have
a single blower; Sizes
700 and 1200 have dual
blowers.)
Model ADF
300/500/700/1200
with Horizontal Discharge
Model ADF
300/500
with Vertical Discharge
Model ADFH
300/500/700/1200
with Vertical Discharge
Model ADF
700/1200
with Vertical Discharge
On Model ADF Sizes 700
and 1200 with vertical dis-
charge, the extra cabinet
is required for space to
mount the blower motor.
On all Model ADFH sys-
tems, the extra cabinet is
required to keep the motor
out of the airstream of the
higher temperature dis-
charge air.
Electrical
Compartment
Burner / Gas Train / Electrical Compartment Motor and Blower
Model ADF
300 showing
Compartments
Electrical
Components
CODE Description Location P/N
1 PC Board Assembly (circuit board with diagnostic lights, See Code 1A)
Electrical Compartment
151263
1A Replacement Light for PC Board Assembly (Code 1) 125189
1B Replacement Relay for PC Board Assembly (Code 1) 151271
2
Relay, SP-ST or
SP-DT, 24V Coil
Relay
Units manufactured after 8/11
Control Compartment
211411
Relay Socket Base 211415
Replacement Kit for units mfgd prior to 8/11 (replaces P/N's 14747, 98118, 103317) 263527
Relay, SP-ST or
Sp-DT, 120V Coil
Relay
Units manufactured after 8/11
Control Compartment
211414
Relay Socket Base 211415
Replacement Kit for units mfgd prior to 8/11 (replaces P/N's 103318 & 103319) 263530
3
Time Delay Relay (for freezestat bypass), T & B Agastat #VTM1ULA Electrical Compartment 89661
Time Delay Relay (Low Fire), 24V Coil, Thermodisc #F12S20, Style 305005 Control Compartment 89254
4 Starter Relay, Essex #91-102006-13088, SPDT, 24V coil Electrical Compartment 110656
5 Energy Cutoff Limit Device Brnr/Cntrl Compartment 82414
6 Limit Switch, Automatic
ADF, 130°F Blower Section 122856
ADFH, 170°F Blower Section 57953
7 High Temperature Limit, Manual Reset
ADF, 135°F Blower Section 122858
ADFH, 175°F Blower Section 122990
8 High Ambient Cutoff, J/C #A19AAF-12C Electrical Compartment 126170
9 Freezestat, J/C #19AAF-12C Blower Compartment 126170
10 Firestat, Honeywell #L4029E1029, 200°F Blower Discharge 42782
11
Low Air Pressure Switch, IS2-0211, set @ .25" w.c.
Electrical Compartment
203932
Low Air Pressure Switch Kit replaces P/N 86986, #FS4197-166 or PPS10175-3043 193806
12
High Air Pressure Switch, IS2-2075055F5193, set @ -.75" w.c.
Electrical Compartment
203933
High Air Pressure Switch Kit replaces P/N 86987, #FS4197-164 or PPS10175-3041 193807