Before using your air conditioner, please read this manual carefully and keep it for future reference. ONE-TWO / ONE-THREE SPLIT-TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing the product. If the power cord is damaged, replacement work shall be performed by authorised personnel only. Installation work must be performed in accordance with the national wiring Standards by authorised personnel only.
CONTENTS SAFETY PRECAUTIONS Warning ...........................................................................................................................................2 Caution ............................................................................................................................................2 INSTALLATION INSTRUCTIONS Selecting installation place...............................................................................................................3 Accessories .....
SAFETY PRECAUTIONS Read the follow SAFETY PRECAUTIONS carefully before installation. Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model to be installed. Incorrect installation due to ignoring of the instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury.
INSTALLATION INSTRUCTIONS Selecting installation place More than 15cm Read completely, then follow step by step. Indoor unit More than 12cm Do not expose the indoor unit to heat or steam. More than 12cm Select a place where there are no obstacles in front or around the unit. Make sure that condensation drainage can be conveniently routed away. More than 2.0m Do not install near a doorway. Fig.1 Ensure that the space on the left and right of the unit is more than 12cm.
INSTALLATION INSTRUCTIONS Tools needed for installation: Level gauge Screwdriver Electric drill,Hole core drill ( 65mm) Flaring tool set Specified torque wrenches: 1.8kgf.m, 4.2kgf.m, 5.5kgf.m, 6.6kgf.m(different depending on model No.
INSTALLATION INSTRUCTIONS 3 >15cm >15cm 3 2 2 1 >12cm 1 >12cm >12c m Air filter 7 Air filter SET TEMPERATURE ( C) FAN HIGH MED LOW AUTO COOL DRY HEAT TEMP MODE 7 SWING 9 >2.0m SET TEMPERATURE ( C) 3 FAN HIGH MED LOW AUTO COOL DRY HEAT >2.
INSTALLATION INSTRUCTIONS Indoor unit installation Correct orientation of Installation Plate 1. Fit the Installation Plate 1. Fit the installation plate horizontally on structural parts of the wall with spaces around the installation plate. 2. If the wall is made of brick, concrete or the like, drill eight (8) 5mm diameter holes in the wall.Insert Clip anchor for appropriate mounting screws. 3. Fit the installation plate on the wall with eight (8) type “A” screws. Fig.
INSTALLATION INSTRUCTIONS 2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack. Right-hand piping Rear-right piping Connective pipe installation 1. For the left-hand and right-hand piping, remove the pipe cover from the side panel. 2. For the rear-right-hand and rear-left-hand piping, install the piping as shown. Bend the connective pipe to be laid at 43mm height or less from the wall. 3.
INSTALLATION INSTRUCTIONS 5. Piping and wrapping Bundle the tubing, connecting cable, and drain hose with tape securely, evenly as shown in Fig.12 Because the condensed water from rear of the indoor unit is gathered in ponding box and is piped out of room. Do not put anything else in the box. Indoor unit Connective cable Ponding box Pipe room Connective pipe Wrapping belt CAUTION Connect the indoor unit first, then the outdoor unit. Do not allow the piping to let out from the back of the indoor unit.
REFRIGERANT PIPE CONNECTION Settlement of outdoor unit A Anchor the outdoor unit with a bolt and nut 10 tightly and horizontally on a concrete or rigid mount. Air inlet B Air inlet Outdoor unit dimension Mounting dimensions mm(WxHxD) A(mm) B(mm) 860x845x345 562 357 875x655x357 677 370 990x965x355 623 366 Air outlet Fig.14 Drain joint installation Fit the seal into the drain elbow, then insert the drain joint into the base pan hole of outdoor unit, rotate 90 to securely assemble them.
ELECTRICAL WORK Flare nut C: Putting nut on Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal.(not possible to put them on after flaring work) Copper tube D: Flaring work Firmly hold copper pipe in a die in the dimension shown in the table below. Fig.18 "A" Bar Outer diam. (mm) 6.35 9.53 12.7 Handle Bar Yoke A(mm) Max. 1.3 1.6 1.8 Cone Min. 0.7 1.0 1.0 Copper pipe Clamp handle Red arrow mark Fig.
ELECTRICAL WORK Connect the cable to the indoor unit Panel NOTE: Before performing any electrical work, turn off the main power to the system. 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type designation H07RN-F or heavier cord. 3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw as shown in Fig.22. 4.
ELECTRICAL WORK Minimum norminal cross-sectional area of conductors: Rated current of appliance (A) Nominal cross-sectional area 2 (mm ) 0.75 >3 and <6 1 >6 and <10 >10 and <16 1.5 >16 and <25 2.5 NOTE: The supply voltage must be consistent with the rate voltage of the air conditioner.
ELECTRICAL WORK One-three(9000Btu/h*3) type, (12000Bty/h*3) type One-three(9000Btu/h*2+12000Btu/h) type, One-three(12000Btu/h*2+24000Btu/h) type, Outdoor unit XT1 LN L N 1 L N 1 L N 1 XT1 XT2 Outdoor unit power LN 1 2 LN 1 2 LN 1 2 Indoor unit A1 Indoor unit A2 Indoor unit B Cooling only models Fig.
AIR PURGING CAUTION CAUTION CAUTION CAUTION After the confirmation of the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation.
AIR PURGING When relocate the unit to another place, perform evacuation using vacuum pump. Make sure the refrigerant added into the air conditioner is liquid form in any case. (Not applicable to the units adopt freon R22 ) Refrigerant Outdoor unit Indoor unit A Gas side C Liquid side D B Caution in handling the packed valve Open the valve stem until it hits against the stopper. Do not try to open it further. Securely tighten the valve stem cap with a spanner or the like.
TEST RUNNING Safety and leakage check Electrical safety check Perform the electric safe check after completing installation: 1. Insulated resistance The insulated resistance must be more than 2M . 2. Grounding work After finishing grounding work, measure the grounding resistance by visual detection and grounding resistance tester. Make sure the grounding resistance is less than 4 . 3.
CS449-I 202000191021 20100330