Cappa Aspirante Cooker hood CA 962 ALU
Contenuti - Contenents Generalità .................................................. General Data .............................................. 4 13 Componenti ............................................... Components ............................................... 4 13 Avvertenze per la Sicurezza ...................... Safety Warnings ......................................... 4 13 Installazione ............................................... Installation ............................................
Contenuti - Contenents Avvertenze per la Sicurezza .................... Safety Warnings ....................................... 11 20 Uso ............................................................ Operation .................................................. 11 20 Manutenzione ........................................... Maintenance .............................................
Part 1 - INSTALLATION INSTRUCTIONS 1 - GENERAL DATA This hood has been designed to be wall-mounted above a cooking hob with one side resting against a wall. It works either by suction (external outlet) or filter (internal recycling). Because of the complexity and weight of the hood, its installation should be carried out by qualified staff, taking care to respect all local regulations on air discharge. The manufacturer cannot be found liable for any damage due to improper installation.
Part 1 - INSTALLATION INSTRUCTIONS 3.8 - Before carring out any kind of maintenance or cleaning, disconnect the hood from the mains supply. 3.9 - If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then this must be of the room sealed or balanced flue type. If other types of flue or appliance are fitted ensure that there is an adequate supply of air into the room.
Part 1 - INSTALLATION INSTRUCTIONS 4.2 - Installation of the hood canopy C 1 - Drilling the wall a) Using the cardboard template provided, mark on the wall the centres of holes 1 for fixing of the hood canopy C. The centre of hole 2 for fixing the chimney, (fig. 5a) air outlet directed upwards or towards the wall, (fig.
Part 1 - INSTALLATION INSTRUCTIONS 3 - Fitting the hood canopy C to the wall a) Remove the lower grill and the active charcoal filter if present (see paragraph on maintenance). b) Fit the support rod B using the two screws K (3,5x9,5) provided (fig. 8). c) Hook the hood canopy C to the eye B K bolts O fixed in holes 1 (fig. 9). d) Adjust the support rod B so that it pushes against the wall (fig. 10). e) Adjusting position (fig. 11).
Part 1 - INSTALLATION INSTRUCTIONS 1 - Drilling the shelves: a) Using the cardboard template provided, and taking hole “B” as a point of reference, drill the shelves along the central axis to allow the passage of the chimney. The chimney must be inserted into the shelves before it is fixed to the hood canopy C (fig. 12).
Part 1 - INSTALLATION INSTRUCTIONS 17 18 S07_16 - Remove the plug from the upper part of the ducting fan unit (fig. 17), as it is not possible to insert the flange F with the plug in place. - Fit the flange F Ø120 or 150 mm (fig. 18), replace the plug. · Air outlet directed to the right or left hand side (fig. 4a-b). - Remove the four screws fastening the plastic frame, as shown in fig. 16. - Fit the ducting spigot R (fig. 19) and replace the four screws removed as above.
Part 1 - INSTALLATION INSTRUCTIONS 4.4 - Ducting or recirculation fitting 4.5 - Connection to power supply and checking of good working order 25 S07_23 1 - Ducting fitting. This is possible for all forms of installation: a) Connect the air outlet to the external ducting system. b) Remove the activated charcoal filter (if there is one) inside the hood canopy (see Maintenance). 2 - Recirculation fitting This is only possible with the air outlet directed upwards.
Part 2 - USE AND MAINTENANCE INSTRUCTIONS 1 - SAFETY WARNINGS 1.1 1.2 1.3 1.4 It is most important that all the warnings shown in paragraph 3 of the Installation Instructions are strictly observed. Moreover, pay special attention to the following warnings during the use and maintenance of the cooker hood: - The grease filters and charcoal filters should be cleaned or replaced as recommended by the manufacturer or more frequently if the hood is used consistently (over 4 hours per day).
Part 2 - USE AND MAINTENANCE INSTRUCTIONS 3.1 - Metal antigrease filters 1 - Cleaning It is necessary to wash these filters at least every two months with a normal detergent; their compact size enables them to be washed also in dishwasher. 2 - Replacement Remove the metal grease filter by removing the filter retaining clips (fig. 29). 29 S36_29 3.2 - Activated carbon filters 1 - How they work The activated carbon filter can hold odours until it reaches total saturation.
22
23
4329410_02 - 040122