Technical data
M219 MK2 Re:connect
14
[4] M219-Link
- M217 Display connection
- M200/ M203 TV interface
The external display M217 or a M200- /
M203 interface can be connected to
the M219
-Link
connector.
Connection is made using a straight
through (not crossed), 4-core
telephone cable with an RJ11 plug
(6P4C-Modular) connected to the M219
LINK socket.
1
only available at side room amplifiers with
address X1-X4
Front view of RJ11 Connector
² Comment
A 3-core cable with screening is
recommended. In this case, no further
cable would be necessary if you added
an additional display at a later stage.
[5] IR-LINK
Connection for IR receiver or wall-
mounted remote control
If it is not possible or not required that
the M219 is controlled directly with a
remote control, a wall-mounted remote
controller (e.g. M218) or and external
IR eye (MR-204) can be connected to
the
IR-LINK
connector.
Connection to the IR receiver or the
wall-mounted remote controller is
made using a screwable Phoenix plug
connector.
Revox recommends the use of a 3-
core, screened cable² (microphone
cable), where the screening is used as
an earth.
This cable may not be longer than 30
meters. Please refer to the label for the
correct cabling:
+ Positive feed -
VCC
IN IR Signal -
Data
- Earth -
GND
Tthe maximum number of IR receivers
per M219 is 3.
IR commands
The M219 accepts all RC5 commands
and carries out those that are intended
for it. All others are transferred on to
the Multiroom central unit.
VC CGND
A
B