Technical data

M219 MK2 Re:connect
11
(3) Voltage input IN (from serial # 2000)
Using the voltage input IN on the M219, the local audio input LOCAL IN 1 can be
activated by the application of 5 – 24 VDC. This means that as soon as the
voltage is present at IN, the M219 switches on automatically and selects the
input LOCAL IN 1. When the voltage is removed from input IN, the M219
switches off again automatically, as long as no other source apart from LOCAL
IN 1 was addressed.
With DIL switch (3), you can define whether the volume control is
handled by the M219 (
Floating Volume
) or the connected (TV) device
(
Fixed Volume
). With
Fixed Volume
, the M219’s volume control is
deactivated and the audio signal at LOCAL IN 1 is transmitted with a
fixed strength. In this way, volume control is carried out with the TV
remote control.
The volume control setting set by DIL switch 3 only has an effect on the local
audio input LOCAL IN 1. All other sources are unaffected and operate normally.
LOCAL IN 1
DIL switch
3
DIL position
Floating Volume Off
3
Fixed Volume On
3
Application: Many devices output a voltage as soon as they are switched
on. If you connect the voltage output of such a device with the
IN voltage input on the M219 and the audio output with the
local audio input LOCAL IN 1, the M219 will switch on
automatically with the other device and transmit the sound.
If your device doesn’t have a voltage output, you can supply
voltage to the input using a sensor-switch multiple socket
outlet (Master/Slave socket outlet) and a normal plug-in power
supply (5-24 V= / DC). Please refer to the diagram on Page 12.
INFO