MG3P Technical Specs
MG3P
High Efficiency / Direct Vent
or Non Direct Vent
Condensing Upflow Gas Furnaces
Induced Draft - 92.1% AFUE
Input 54,000 - 108,000 Btuh
The high efciency upow gas furnace is especially
designed for Manufactured Housing. It may be installed
in a utility room, or enclosed in a closet. The extended
ush jacket provides a pleasing “appliance appearance.”
Design certied by CSA for application in Canada and the
United States.
• 100% fired and tested: All units and each component
are tested on the manufacturing line.
• Best packaging in the industry: Unique corner post
design assures product will arrive to the homeowner
dent free.
• 30 second blower delay: At start-up assures a warm
duct temperature at furnace start-up. Adjustable blower
off settings (60, 90, 120 and 180 seconds).
• 30 second post purge: Increases life of heat exchanger.
• Hot surface igniter: Innovative application of an
appliance type igniter with a 20 year history of reliability.
Utilizes proven Smartlite
®
technology.
• Color coded wire harness: Designed to t the
components, all with quick-connect ttings for ease
of service and replacement.
• Flexible category IV venting system: May be vertically
or horizontally vented using either a one-pipe or two-
pipe system for maximum exibility in installation.
• High Static Blowers: All models equipped with high
static blowers.
• Low Boy Height: Easy to apply in low ceiling
applications, works well with taller high SEER coils,
easier to handle and install.
• Tubular primary heat exchanger: Heavy gauge
aluminized steel heat exchanger and stainless steel
secondary heat exchanger assures a long life.
• 90 second fixed cooling cycle blower-off delay
(TDR): Increases cooling performance when matched
with a Nortek Global HVAC coil.
• High efficiency blower kits: Maximize efciencies.
On select units, a SEER improvement of up to 1 point
is realized.
• Multi-speed direct drive blower: Designed to give a
wide range of cooling capacities. Switches on PCB,
provide ultra easy motor speed selection.
• LP convertible: Simple burner orice and regulator
spring change for ease of convertibility.
• Diagnostic lights for easy troubleshooting without
counting flashes: Dedicated light for ame signal
strength and 2 lights in combination to indicate all
other fault codes with easy to recognize states without
counting ashes.
• Incorporates integrated control board: With
connections for electronic air cleaner and humidier.
• Two piece door design: Enhances furnace appearance
and uses captured screws to prevent losing door screws.
• Seated vestibule: Reduces burner and inducer sound
levels.
FEATURES and BENEFITS
TECHNICAL
SPECIFICATIONS
For California installations in SCAQMD only: This furnace
does not meet the SCAQMD Rule 1111 NOx emission limit
(14 ng/J), and thus is subject to a mitigation fee of up to
$450. This furnace is not eligible for the Clean Air Furnace
Rebate Program: www.CleanAirFurnaceRebate.com.