MG3P Installation Manual

34
MAINTENANCE
WARNING:
ELECTRICAL SHOCK, FIRE OR
EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death or property
damage.
Improper servicing could result in dangerous
operation, serious injury, death or property
damage.
Before servicing, disconnect all electrical
power to furnace.
When servicing controls, label all wires prior
to disconnecting. Reconnect wires correctly.
Verify proper operation after servicing.
AVERTISSEMENT :
RISQUE DE DÉCHARGE ÉLECTRIQUE,
D’INCENDIE OU D’EXPLOSION
Le non-respect des avertissements de sécurité
pourrait entraîner des blessures graves, la mort ou
des dommages matériels.
Un entretien inapproprié peut provoquer un
fonctionnement dangereux, des blessures graves, la
mort ou des dommages matériels.
Avant toute intervention, couper l’alimentation
électrique du générateur d’air chaud.
Pour l’entretien des commandes, étiqueter tous
les fils avant de les débrancher. Rebrancher les
fils correctement.
Vérifier le bon fonctionnement après l’intervention.
Proper maintenance is most important to achieve the best
performance from a furnace. Follow these instructions for
years of safe, trouble free operation.
These maintenance instructions are primarily intended to assist
qualified technicians experienced in the proper maintenance
and operation of this appliance.
Always reinstall the doors on the furnace after servicing or
cleaning/changing the filters. Do not operate the furnace
without all doors and covers in place.
Verify the thermostat is properly installed and will not be
affected by drafts or heat from lamps or other appliances.
To achieve the best performance and minimize equipment
failure it is recommended that a yearly maintenance checkup
be performed.
At a minimum, this check should include
the following items:
DIAGNOSTIC DESCRIPTION GREEN LED RED LED
Control Fault (No Power) Off Off
L1/Neutral Polarity Fault Flash Flash
1 Hour Lockout Alternating Flash
Normal Operation On On
Pressure Switch Closed Fault On Flash
Pressure Switch Open Fault Flash On
Open Limit Switch Fault Flash Off
Motor Fault On Off
DIAGNOSTIC DESCRIPTION YELLOW LED
Low Flame Sensor Signal Continuous Flash
Flame Present On
Table 7. MG3S Furnace Control Board Fault
Conditions
DIAGNOSTIC
DESCRIPTION
GREEN
LED
RED
LED
Fixed
Speed
Furnaces
Control Fault (No Power) Off Off
Normal Operation On On
Motor Fault On Flash
Twin Fault (no motor fault) Flash On
Communications Fault Flash Flash
Variable
Speed
Furnaces
Control Fault (No Power) Off Off
Normal Operation On On
Motor Fault On Flash
Communications Fault Flash Flash
Table 8. MG3S Motor Control Board Fault
Conditions