Revolabs HD™ Single/Dual Wireless Microphone System Models: 02-HDSGL, 02-HDDUAL, 04-HDSGLEU and 04-HDDUALEU User and Set-up Guide
© 2009 REVOLABS, INC. All rights reserved. No part of this document may be reproduced in any form or by any means without express written permission from Revolabs, Inc. Product specifications are subject to change without notice. Revolabs HD™ Single & Dual Manual 01-HDSGLMAN-PAP-11 March 2010 (Rev 1.
Contents Safety and General Information .................................................................................................................... 1 Introduction.................................................................................................................................................... 3 System Components ................................................................................................................................
Safety and General Information Please read the following information to ensure safe and efficient use of your Revolabs system. FCC User Information FCC Registration Number: 0014898290 FCC ID: T5V02HDTRX Revolabs HD™ Dual Base Station FCC ID: T5V01HDEXEMIC Revolabs Executive HD ™ Microphone FCC Notice to Users Users are not permitted to make changes or modify the equipment in any way. Changes or modifications not expressly approved by Revolabs, Inc.
Export Law Assurances This product is controlled under the export regulations of the United States of America and Canada. The Governments of the United States of America and Canada may restrict the exportation or re-exportation of this product to certain destinations. For further information contact the U.S. Department of Commerce or the Canadian Department of Foreign Affairs and International Trade. The use of wireless devices and their accessories may be prohibited or restricted in certain areas.
Introduction Congratulations on your purchase of a Revolabs Wireless Microphone System! This system utilizes 1.9 GHz DECT technology, and high band-width audio from multiple wireless microphones, enabling clear, reliable, un-tethered communications in recording, audio/video conferencing, speech recognition, VOIP communications, sound re-enforcement as well as many other environments requiring clear audio capture.
Acoustic echo cancellation (AEC) Feedback elimination Level control Equalization Noise cancellation The system is designed to optimize audio capture/reproduction by providing: Consistent audio input from all participants Minimum room noise Mute control Wireless encryption Automatic channel selection Full duplex audio The Charger Base charges the HD Wireless Microphones and stores them when not in use.
To Install the Base Station: 1. Plug the power cord into an appropriate outlet 2. Connect the necessary outputs and inputs Revolabs HD™ Base Station Audio Connections There are (2) 3.5mm balanced inputs and (2) 3.5mm balanced outputs on the back panel of the unit providing access to each channel’s audio signal. The three terminals correspond to: Tip = Positive + Ring = Negative – Sleeve = Shielded Ground There are one or two output channels representing a separate channel for each microphone.
Using the Rear Panel Configuration DIP Switches off on 12345678 DIP Switch Feature Off (Default) On Individual Outputs Mixed Output No LPF LPF 1 Output Mixing 2 Low Pass Filter 3 Audio Output Level Line Level Mic Level 4 Mute Mode Individual Mutes No Mutes Off Off High boost On Off Bass Boost Off On 65' Off Off 50' On Off 30' Off On Flat 5 6 7 8 Microphone EQ Transmit Power Dynamic On On 15' On On Configuration Settings DIP Switch 1- Output Mixing: When DIP Switch 1 is OFF(defa
DIP Switch 5&6 – Microphone EQ: There are four EQ options for the microphone outputs of the Base Station. One of these options can be activated for both microphones. DIP Switch 7&8 - Transmit Power: The transmit power of the Base Station can be adjusted to help reduce the operational radius of a Revolabs HDTM System in order to prevent interference from other Revolabs products, or from other devices operating in the same frequency.
Revolabs HD Wearable Microphones turn on and mute automatically when removed from Charger Base, to reduce noise while being attached. To use the HD Wearable Microphone: 1. Remove the microphone from the Charger Base. 2. Attach the microphone to clothing or to a lanyard, position microphone just above the sternum or breastbone, within 6 - 12 inches (15 – 30cm) from the mouth is recommended. Make sure microphone is attached securely with the microphone LED indicator pointed up toward mouth. 3.
Using the HD Omni-Directional Tabletop Wireless Boundary Microphones The HD Omni-directional Tabletop Wireless Boundary Microphones enable multiple conference attendees to use a single microphone. 360 º pickup pattern 1 2 3 6 5 4 1. 2. 3. 4. 5. 6. LED display — visual status for mute, un-mute, and pairing. Mute button — press to mute, un-mute and pair microphone. Audio jack — accepts a 2.5mm plug. Charging port — docks to Revolabs HD Charger Bases. Rubber feet — non-slip, vibration absorbing pads.
If the microphones are placed too far from the Base Station (~65 feet or 20 meters) the connection will be dropped (LED flashes all colors) and the microphone will mute. After 15 seconds the microphone will beep 5 times, and will continue beeping every 30 seconds to indicating it’s out of range. Move the microphone closer to the Base Station and the connection will automatically be reestablished to its original state, and the beeping will cease.
3. With the microphone in position, un-mute the microphone by pressing and releasing the Mute button (confirm by a flashing GREEN LED). 4. To turn microphone off, return the microphone unit to the Charger Base or press and hold the Mute button for ~10 seconds until the LED turns solid RED and release button. If the microphones are placed too far from the Base Station (~65 feet or 20 meters) the connection will be dropped (LED flashes all colors) and the microphone will mute.
Note: The Adapter does not provide phantom power or bias current so it cannot be used with condenser or electret microphones. 2. With the microphone attached, un-mute the Adapter by pressing and releasing the Mute button (confirm by a flashing GREEN LED). Note: to use. If the microphone has an on-board mute switch, this switch must also be un-muted prior 3.
1. 2. 3. 4. 5. Audio Out port — accepts the 2.5mm plug for the earpiece. Charging Port — docks to all Revolabs HD Charger Bases. Mute button — press to mute, un-mute and pair microphone. LED display — visual status for mute, un-mute, and pairing. TA4F connector — connects to Countryman microphone cable. To use the HD Wireless Adapter for Countryman Microphone: 4. Remove the Microphone Adapter from the Charger Base.
To pair an individual microphone to the Base Station: 1. Turn the microphone OFF (no LED activity). If the microphone is ON, press and hold the Mute button for 10 seconds until the LED turns solid RED then release the button to turn the unit off. (do not release the button when you hear two beeps). 2. Place the microphone unit into pairing mode by holding the Mute button down for seven seconds. The LED will turn solid RED. Release the Mute button. The microphone is now in pairing mode. 3.
Important: The Lithium Polymer rechargeable batteries that power the microphones are not user serviceable. Please contact Revolabs (www.revolabs.com) or your AV service provider for replacement instructions and to assure the proper disposal method is used. Warning: Never dispose of batteries in a fire because they may explode. Either a solid RED LED (charging) or solid GREEN LED (100% charged) will appear to confirm that the microphone is inserted properly in the Charger Base.
Revolabs HD™ Indicator LEDs The following tables show activities associated with the various states shown by the LEDs: Equipment Use Microphone LED Microphone in Charger Base Microphone not in Charger Base Solid RED Solid GREEN OFF Base Station Channel LEDs OFF OFF OFF Two RED flashes every 1.5 seconds One GREEN flash every 1.5 seconds Solid RED Two RED flashes every 1.5 seconds GREEN flash every 1.
Warranty Revolabs, Inc. warrants this product to be free of manufacturing defects. Repair or replacement of any defective part or unit (at the discretion of the Seller) will be free of charge for the period of one year. Any attempt by the user to alter the equipment, or equipment damaged by negligence, accident, or Acts of God voids this warranty. The Seller shall not be liable for any consequential damage resulting from the malfunction of this product.
Specifications Dimensions, (L, W, H) and Weight: Single/Dual Base Station Single/Dual Charger Base Wireless Microphones Shipping Weight 5.19‖ (13.18 cm) x 3.25‖ (8.25 cm) x 1.0‖ (2.54 cm), 0.325 lbs (0.147 kg) 4.6‖ (11.75 cm) x 3.125‖ (7.9 cm) x 1.0‖ (2.54 cm), 0.325 lbs (0.147 kg Wearable: 0.9‖ (2.3 cm) x 0.8‖ (2.0 cm) x 2.6‖ (6.6 cm), 0.05 lb (0.02 kg) TableTop: 1.5‖ (3.8 cm) x 0.8‖ (2.0 cm) x 3.3‖ (8.4 cm), 0.05 lb (0.02 kg) XLR Adapter: 0.9‖ (2.3 cm) x 0.8‖ (2.0 cm) x 4.0‖ (10.2 cm), 0.05 lb (0.
Index Adjusting the Volume, 8 Base Station, 4 Back Panel, 4 Front Panel, 4 Channel LED indicators, 5 Channels, 5 Charger Bays, 13 Charging the Batteries, 13 First-time use, 13 Recharging, 13 Connections, 5 Earpiece, 5 Full-Duplex, 5 Indicator LEDs, 15 Input Connectors, 5 LED indicator, 13 MC/TDMA/TDD, 3 Microphone Charging port, 7 Earpiece Jack, 7 LED Display, 7 Mute Button, 7 Pocket Clip, 7 Microphones, 7 Pairing, 12 Power Cord Receptacle, 13 Power In Receptacle, 5 Power Module, 13 Safety Information, 1 S
Note: Microphones must be fully charged and paired to the Base Station prior to first use. Revolabs HD™ Single & Dual Manual 01-HDSGLMAN-PAP-11 March 2010 (Rev 1.