User Manual

Tandberg™ Installation (Tandberg Edge 95 shown for example)
This information is meant to be illustrative only. Consult your Tandberg
Videoconferencing System Administrator Manual for the specific instructions.
Step 1 Step 2
1. Plug the black RCA connector on one end of Cable C into Tandberg video-
station <Audio Out 1>, and then plug the black RCA connector on the other
end into the Fusion Base Station <Conf In>. The other RCA connector is not
used.
2. Plug one XLR connector of Cable D, XLR to XLR, into Tandberg video-
station <Mic 1 Input> and the other XLR connector into the Fusion Base
Station Mic Level Output <Conf Out (Mics)>.
To configure the Tandberg system:
Select the button from the main screen to access the System menu.
Go to Audio settings
Confirm or modify the following settings:
Input 1 - MIC
Output 1 - ON
Audio Leveling - OFF
Echo Canceller - OFF
Adjust the audio Input Level if necessary.
Speak into the Revolabs microphones that are connected to the audio line inputs.
The audio meter should peak at about 5 dB.
Page 14
Set-Up Guide
Multiple Fusion Systems
There are two settings that must be adjusted when more than one Fusion
system is used within a 100’ (30.5 m) range: frequency and transmit power
level. These settings will enable several Fusion systems to be used near each
other, but not interfere with each other. Interference between systems can
cause occasional audio noise and signal dropouts on affected systems. Building
conditions may influence this distance.
NOTE: Even using the settings below, the 8-Microphone Fusion
System requires 40 feet (12.2 m) between systems.
Setting the Transmit Power Level for Multiple Fusion Systems
Setting the Transmit Power Level for Multiple Fusion SystemsSetting the Transmit Power Level for Multiple Fusion Systems
Setting the Transmit Power Level for Multiple Fusion Systems
In confined settings where multiple Fusion systems are used, or where audio
interference is likely, it may be necessary to reduce the transmit power levels.
The transmit power level between the microphones and Fusion Base Station can
be set to the following three levels:
Highest power level (default) – 100 feet (30.5 m) maximum operating
distance between Microphone and Fusion Base Station DIP Switches #1 and
#2 are OFF (page 18).
Medium power level – 30 feet (9 m) maximum operating distance between
Microphone and Fusion Base Station . DIP Switch #1 is ON and DIP
Switch #2 is OFF (page 18).
Lowest power level – 8 feet (2.4 m) maximum operating distance between
Microphone and Fusion Base Station . DIP Switch #2 is ON and DIP Switch
#1 is OFF (page 18).
Frequency Settings
Frequency SettingsFrequency Settings
Frequency Settings
Frequency should be alternated to different frequency ranges, A and B. So an
example of five conference rooms in a row would be configured:
To configure the Fusion to frequency mode A, Dip Switch #3 is ON and DIP
Switch #4 is OFF. Frequency mode B - Dip Switch #4 is ON and DIP Switch #3
is OFF. (page 18).
NOTE: The Fusion system must be powered off and back on for any
DIP Switch changes to take effect.
Conference
ConferenceConference
Conference
Room
RoomRoom
Room
1
11
1
2
22
2
3
33
3
4
44
4
5
55
5
Frequency
FrequencyFrequency
Frequency
A
AA
A
B
BB
B
A
AA
A
B
BB
B
A
AA
A
Page 19
Revolabs Fusion™