User Manual
Table Of Contents
- Rev 1.1
- Revolabs Fusion™ Wireless Microphone System
- Installation and User’s Guide
- Page #
- Table of Contents
- Part Numbers Covered in This Document
- Page #
- Revolabs Fusion™
- Page #
- Installation Guide
- Revolabs Fusion™
- Page #
- Installation Guide
- Page #
- Fusion Set-up
- Page #
- Revolabs Fusion™
- Safety and General Information
- Page #
- Installation Guide
- Revolabs Fusion™
- Audio Conferencing
- Video Conferencing
- Page #
- Installation Guide
- Lifesize Installation
- Specifications
- Page #
- Revolabs Fusion™
- Warranty
- Page #
- Installation Guide
- Revolabs Fusion™
- Page #
- Polycom Installation
- Page #
- Installation Guide
- Page #
- Revolabs Fusion™
- Revolabs Solo™ Indicator LED
- Page #
- Installation Guide
- Page #
- Revolabs Fusion™
- Page #
- Installation Guide
- Page #
- Revolabs Fusion™
- Using the Solo XLR Microphone Wireless Adapter
- Page #
- Installation Guide
- Page #
- Revolabs Fusion™
- Tandberg Installation
- Page #
- Installation Guide
- Page #
- Revolabs Fusion™
- Using Solo Tabletop Wireless Boundary Microphones
- Page #
- Installation Guide
- Page #
- Revolabs Fusion™
- Pairing Wireless Microphones to Fusion Base Station
- Page #
- Installation Guide
- Page #
- Revolabs Fusion™
- Using Revolabs Microphones and Microphone Adapters
- Using Revolabs Solo™ Wearable Wireless Microphone
- Page #
- Installation Guide
- Page #
- Revolabs Fusion™
- Details about the Revolabs Fusion
- Fusion Front Panel
- Page #
- Installation Guide
- Page #
- Using the Revolabs Fusion™ Charger Base
- Charging the Microphone Batteries
- Revolabs Fusion™
- Using the Revolabs Fusion™ IR Remote Control
- Page #
- Installation Guide
- Page #
- Fusion Back Panel
- Revolabs Fusion™
- Programming Port: DIP Switches
- Page #
- Installation Guide
- Programming Ports DIP Switches Used for Phone Answering
- Setting Phone Answering Mode
- Page #
- Revolabs Fusion™
- Programming Ports DIP Switch Used for Muting Option
- Setting the Mute Option
- Page #
- Installation Guide
- Programming Port Settings for Multiple Fusion Systems
- Setting the Transmit Power Level for Multiple Fusion Systems
- Frequency Settings
- Page #
- Revolabs Fusion™
Pairing Wireless Microphones to Fusion
Base Station
If you selected your microphones separately with the 01-8FUSION-NM or 01-
4FUSION-NM Fusion part numbers, you must first establish a connection
between your microphones to the Fusion Base Station. This is called “pairing”.
Pairing creates a link with a unique electronic serial number between the Solo
wireless microphone and the Fusion Base Station. When the microphone and
Base Station have been previously paired, the microphone will automatically try
to connect to the Base Station whenever it is lifted from the Charger Base.
Note: Microphones in new systems must be paired to the Base Station
with each microphone assigned to a unique channel on the base unit.
Remember, microphones are always muted (flashing RED LED) when they are
removed from the Charger Base and the Mute button needs to be pressed to
make it “live” (flashing GREEN LED).
A microphone that is not paired will be indicated by either cycling RED-GREEN,
or RED-YELLOW-GREEN LED patterns. A Base Station LED that is not paired
to a microphone will not show any activity on the LED (make sure unit is first
powered on by observing GREEN power LED on the front panel).
When the microphone and Fusion Base Station are paired, both microphone
and channel LEDs will flash RED as microphones are removed from the Charger
Base and flash GREEN when un-muted.
To pair the microphone to the Fusion Base Station:
Turn the microphone OFF (no LED activity). If the microphone is ON, press
and hold the Mute button for 10 seconds until the LED turns solid RED (do not
release when you hear two beeps). Release the button to turn the unit off.
Page 14
Installation Guide
Page 25
Revolabs Solo™ Wearable Microphones turn on and mute automatically when
removed from Charger Base, to reduce noise while being attached. The
microphone has a clip on the back which allows the microphone to be easily
attached onto a shirt pocket, blouse, lapel or lanyard.
To use the Wearable Microphone:
• Remove the microphone from the Charger Base.
• Attach the microphone to clothing or to a lanyard close to the mouth,
within 6 - 12 inches (15 – 30cm) is recommended. Make sure microphone
is attached securely with the microphone port pointed up toward mouth.
• With the microphone in the wearing position, un-mute the microphone by
pressing and releasing the Mute button (confirm by viewing flashing GREEN
LED). If the volume is too low, move the microphone closer to the mouth.
• To turn microphones off, return the microphone unit to the Charger Base
or press and hold the Mute button for ~10 seconds until the LED turns
solid RED and release button.
• If the microphones are moved out of range of the Base Station (~100 feet
or 30 meters) the connection will be dropped (LED flashes all colors) and
the microphone will mute.
• After 15 seconds the microphone will beep 5 times, and will continue
beeping every 30 seconds to remind the user to return the microphone to
the conference room. If the microphone is moved back into range within
15 minutes the connection will automatically be re-established to its
original state, and the beeping will cease. If not, the microphone will turn
off.
Revolabs Fusion™