User Manual

21
6. Lift burners up and away from gas valve orifice.
7. Disconnect wire from spark electrode.
8. Clean venturi of each burner with small bottle brush or compressed air.
9. Remove all food residue and dirt from burner surface.
10. Clean any clogged ports with a stiff wire (such as an opened paper clip).
11. Inspect burners for any damage (cracks or holes). If damage is found, replace with new
burner(s) from manufacturer.
12. Re-install burner(s). Checking to insure that gas valve orifice is correctly positioned
inside each burner/venturi tube. Also, check position of spark electrode.
13. Replace heat plate(s) and cooking grid(s).
14. Connect LP gas tank per “Installing LP Gas Tank” section.
15. Perform leak test per “Checking for Leaks” section.
Cleaning Side Burner
1. Turn LP gas tank valve to “CLOSED.”
2. Turn all control knobs clockwise to the “ OFF” position.
Note: A “poof” sound is normal as the last of the gas is burned.
3. Disconnect LP gas tank per “Disconnecting LP Gas Tank” section.
4. Remove side burner grid.
5. Remove burner by removing the screws that secure the burner to the side shelf.
Before Each Use:
1. Keep the grill area clean and free from any combustible materials, gasoline, and other flammable vapors and liquids.
2. Do NOT obstruct the flow of the combustion of LP gas and the ventilation of air.
3. Keep the ventilation opening(s) of the LP gas tank area free and clear from debris.
4. Visually check the burner flames to make sure your grill is working properly (Figure 9).
5. See sections below for proper cleaning instructions.
6. Check for obstructions of airflow to the burners. Spiders, insects and webs can clog the burner/venturi tube. A clogged burner tube can
lead to a fire.
Cleaning Surfaces
1. Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water.
2. For stubborn surfaces, use a citrus-based degreaser and a nylon scrubbing brush.
3. Rinse clean with water.
4. Allow to air dry.
Cleaning Main Burners
1. Turn LP gas tank valve to “CLOSED.”
2. Turn all control knobs clockwise to the “ OFF” position.
Note: A “poof” sound is normal as the last of the gas is burned.
3. Disconnect LP gas tank per “Disconnecting LP Gas Tank” section.
4. Remove cooking grids and heat plates.
5. Remove burners by removing the fasteners, which secure the burners to the grill
bottom.
CAUTION
1. All cleaning and maintenance should be done
when grill is cool and with the fuel supply
disconnected.
2. Do NOT clean any grill part in a self-cleaning
oven. The extreme heat will damage the finish.
3. Do NOT enlarge valve orifices or burner ports
when cleaning the valves or burners.
1. This grill should be thoroughly cleaned and
inspected on a regular basis.
2. Abrasive cleaners will damage this product.
3. Never use oven cleaner to clean any part of
grill.
NOTICE
Cleaning and Care
Figure 9
Burner Flame Conditions
Use this chart to see if your burners need to be
cleaned.
1-2 in. /
25.4 - 50.8 mm
Normal: Soft blue flames with yellow
tips between 1 in. - 2 in. height.
Needs cleaning: Noisy with hard
blue flames.
Has to be replaced: Wavy with
yellow flames.