User Manual
17
Connecting LP Gas Tank
1. Before connecting, be sure there is no debris caught in the head
of the LP gas tank, head of the regulator valve or in the head of
the burner or burner ports.
2. Connect regulator/hose assembly to tank by turning knob
clockwise until it stops.
Disconnecting LP Gas Tank
1. Before disconnecting, make sure the LP gas tank valve is
“CLOSED.”
2. Disconnect regulator/hose assembly from LP gas tank by
turning knob counterclockwise until it is loose.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this
grill.
3. Place the protective cap cover on the LP tank and store the tank
outdoors in a well ventilated area out of direct sunlight.
Checking for Leaks
Burner Connections
1. Make sure the regulator hose and valve
connections are securely fastened to the burner
and the tank.
2. Visually check the connection between the
burner/venturi tube and orifice.
3. Make sure the burner/venturi tube fits over the
orifice.
W WARNING: Failure to inspect
this connection or follow these
instructions could cause a fire or an
explosion which can cause death,
serious bodily injury or damage to
property.
4. Please refer to diagram for proper installation
(Figure 1 and 2).
5. If the burner/venturi tube does not rest flush
to the orifice, as shown,please contact
1.800.694.0013 for assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak detection solution by mixing
one part liquid dishwashing soap with three
parts water.
2. Make sure control knobs are in the “ OFF”
position (Figure 2).
3. Connect LP gas tank per “Installing LP Gas Tank”
section.
4. Turn LP gas tank valve to “OPEN.”
5. Spoon several drops of solution, or use a squirt
bottle, at all “X” locations (Figures 1, 2 and 4).
a. If any bubbles appear, turn LP gas tank valve to “CLOSED,” reconnect and re-test.
b. If you continue to see bubbles after several attempts, turn LP gas tank valve to “CLOSED” and disconnect LP gas tank, per
“Disconnecting LP Gas Tank” section.
Figure 1: Main Burners
LP Gas
Connection
LP Gas
Valve with
Orifice
Burner/
Venturi
Tube
Figure 2: Side Burner
LP Gas
Connection
LP Gas
Valve with
Orifice
Burner/
Venturi
Tube
Valve Soft Pipe
Connection
Figure 3
Figure 4
X
X
X
X
X
Operating Instructions