Instruction manual

Follow steps below to program the Pattern:
1. Press
MENU to display the main menu on the monitor. Scroll to Pattern and push the
Joystick to the right to enter the pattern menu. Or just press the PTRN key on the
keyboard.
2. Select the desired pattern to be programmed by pushing the
Joystick Up or Down. If
the pattern is not 000, a pattern has already been recorded. Patterns can be overwritten.
3. Press and hold down the
CTRL key while controlling the camera direction and zoom
with the Joystick. The dome will be automatically recorded until you release the CTRL
key. Or Press IRIS Open then the “CTRL” displays. Move the position and the zoom
position. Press IRIS Close then the “CTRL” disappears.
4. Select Save and Exit and push the
Joystick to the right. Press ESC to exit the program
without saving.
5. To edit the title, follow the procedure of the auto scan above to edit titles.
NOTE: Press the HOME key at any programmed position to delete the pattern.
NOTE: If total recording time reaches 500 seconds, it will automatically stop for a moment.
Press PTRN key on the title field to display with the small OSD. Then the screen will show
as below.
PATTERN AREA SETUP
(CTRL KEY)
NUMBER 01
000 00.0%
0001 01.0%
EXIT(ESC TO EXIT)
The setting procedure is the same as above.
3.9 Alarm
ALARM SETUP
NO PRI FUN IN OUT HLD LATCH
01 1 001 NC OFF 03 OFF
02 2 A01 NO OUT1 03 OFF
03 1 --- OFF OUT1 03 OFF
04 1 --- OFF OUT4 03 OFF
05 1 --- OFF OFF 03 OFF
06 1 --- OFF OUT1 03 OFF
07 1 --- OFF OUT1 03 OFF
08 1 --- OFF OUT4 03 OFF
DWELL : 03
RELAY OUT SETUP
SAVE AND EXIT(ESC TO CANCEL)
19