Instruction manual

MOTION SETUP
SENSITIVITY : 12
POSITION : ALL
DELAY : 00 SEC
OUTPUT : OFF
HOLD TIME : 03 SEC
EXIT(ESC TO EXIT)
Set SENSITIVITY: 1~10(22X model) / 1~15(36X model)
Set POSITION: ALL, CENTER
Set DELAY: 0~5 SEC
Set OUTPUT: OFF, OUT1
Set HOLD TIME: 3~99 SEC
Select “AE SETUP” and pushing the
Joystick left or right. Then the AE setup displays.
Refer to the AE SETUP in the camera setup.
6. Set “DWELL TIME”(03-99second)
7. To select the next page of presets, scroll the page by pushing the
Joystick to the Left
on the first and last columns of the menu.
8. Repeat steps 2 through 7 for each additional preset position.
9. Select Save and Exit by pushing the Joystick to the right. Press ESC to exit the Preset
menu without saving.
NOTE: Press the HOME key at programmed preset position(*) to delete a programmed preset
view.
The position, which is marked with
*, already has the preset view assigned. To review the
stored preset, press
PRST key on the *,The camera will show the stored preset scene.
PRESET AREA SETUP
(CTRL KEY)
NUMBER 001
PAN TILT
000.0 000.0
EXIT(ESC TO EXIT)
Hold down the
CTRL key while selecting the desired scene using the Joystick. Current
position will be displayed. Release CTRL key to complete. Or Press IRIS Open then the
“CTRL” displays. Move the desired position and the zoom position. Press IRIS Close then
the “CTRL” disappears. Select Exit and push the Joystick to the right.
16