Instruction manual
SCAN DIR : Set the scan direction, CCW(Counter Clock Wise), CW(Clock Wise) 
SWAP : Swap the start point for the end point. 
DWELL : Set the dwell time at the both end, 01 – 99 seconds 
1. Press the 
SCAN key to enter the auto scan menu directly. Or press the MENU key to 
display the main menu on the monitor. Scroll to Auto Scan and push the Joystick to the 
right. 
2. Select the” NUMBER” and set the desired number by pushing the 
Joystick left or right. 
3. Select the “TITLE” and twist the Joystick to enter the title edit mode. 
4. Twist the Joystick by changing the alphanumeric characters and move the next position. 
Or move down to the character table and press CTRL or IRIS OPEN at the desired 
character then the cursor position moves to the next position automatically. Push the 
Joystick left or right at the “ALL DELETE” field to delete all characters. Push the 
Joystick left or right at the “EXIT” field to finish title edit menu. 
TITLE EDIT MENU 
 A01 
 * 
A B C D E F G H I J 
K L M N O P Q R S T 
U V W X Y Z 0 1 2 3 
4 5 6 7 8 9 ( ) 
 ALL DELETE 
 EXIT (ESC TO EXIT) 
5. Select “MODE” and “SPEED”. 
6. Select “START ANGLE”. Hold down the 
CTRL key while selecting the start position using 
the Joystick. Current panning position will be displayed. Release CTRL key to complete 
the selection of the start position. Or Press IRIS Open then the “CTRL” displays. Move 
the desired position and the zoom position. Press IRIS Close then the “CTRL” 
disappears. To adjust at the 0.1 degree interval, twist the Joystick at the pan field and the 
tilt field. To adjust at the one zoom interval, twist the Joystick at the zoom field. 
7. Select “END ANGLE.” Hold down the CTRL key while moving the Joystick to select the 
end position. The end position angle should be larger than start position. Release the 
CTRL key to complete the selection of the end position. Or Press IRIS Open then the 
“CTRL” displays. Move the desired position and the zoom position. Press IRIS Close 
then the “CTRL” disappears. To adjust at the 0.1 degree interval, twist the Joystick at the 
pan field and the tilt field. To adjust at the one zoom interval, twist the Joystick at the 
zoom field. 
8. Set “SCAN DIR” to CCW or CW. 
9. Select “SWAP”. Set to ON, to exchange the start angle and the end angle. 
13