Specifications

19
SECTION 6.0
SPECIFICATIONS for Pyxis
MECHANICAL
Main Gear Diameter 4.125 inches
Total Gear Reduction 110 : 1
Number of Steps for One Rotation 5280
Degrees for One Step 0.0682º (4.09 arc minutes)
Load capacity 5 pounds maximum
MOTOR
Type Bipolar Stepper
Voltage 12 VDC
Steps for One Rotation 48
Coil Resistance 40 ohms high torque motor with neodymium magnets
MICROCONTROLLER
Type PIC16CE625
EPROM 2K x 14
RAM 128 x 8
I/O Lines 13
EEPROM 128 x 8
Operating Temperature
-40° to +80° C
POWER REQUIREMENTS
Voltage 11.7 to 12.3 volts DC
Current 500 ma for high torque motor
Fuse protection 0.8 amp, PTC reset able
SIZE & WEIGHT
Size 6 inches diameter x 1.5 inches thick without adapters
Clear Aperture 1.65 inches
Weight 27 ounces with adapters
INCLUDED ITEMS
Adapters 2 telescope detachable adapters
Power Supply 12 VDC regulated power supply with 6’ cords
Tools 5/64 and 0.05 hex keys
Software CD disk with Pyxis control software and manual