Warranty

14
7.) When sheetrock is in place, p
ress and bend the final securing tabs flat against
ceiling to lock the FAN in place.
WARNING: Disconnect the AC power before any work is done to any part of
the circuit ReVent is connected to. If you do not understand this warning,
seek the services of a qualified licensed electrician.
WARNING: Copper to copper only. Do not use aluminum wire.
WARNING: Follow all local electrical and safety codes, and NEC (National
Electrical Codes).
CAUTION: If your house wires do not match these colors, determine what
each house wire represents before connecting. You may need to consult a
qualified licensed electrician to determine this safely.
6.) Open the electrical enclosure inside the FAN and connect wiring using the
provided WIRE NUTS, matching wire colors as shown:
black / power
white / neutral
green /
green / ground
120V Line AC
FAN
Close-Up
3 wires 2 wires
2 wires
final securing tabs
sheetrock
(ceiling)
apply even
pressure to
each side of
securing tab
QUICK CONNECT
OR WIRE NUT
Qty:3