Instructions / Assembly
WARNING: Disconnect the AC power before any work is done to any part of 
the circuit ReVent is connected to. If you do not understand this warning, 
seek the services of a qualified licensed electrician.
WARNING: Copper to copper only. Do not use aluminum wire.
WARNING: Follow all local electrical and safety codes, and NEC (National 
Electrical Codes).
CAUTION: If your house wires do not match these colors, determine what 
each house wire represents before connecting. You may need to consult a 
qualified licensed electrician to determine this safely.
16
6.) Disconnect FAN motor from electrical enclosure. Remove the electrical cover 
set screw and slide open the electrical enclosure.
OR
WIRE NUT
Qty:4
(Canada only)
2-WIRE QUICK
CONNECT
Qty:2
(U.S.A. only)
4-WIRE QUICK
CONNECT
Qty:2
(U.S.A. only)
7.) Remove the electrical cover set screw and slide open the electrical enclosure. 
Connect wiring using the provided QUICK CONNECTS (U.S.A.) or WIRE NUTS 
(Canada).
line
ground
line
ground
FAN
ground
housing
ground
line
neutral
line
neutral
FAN
neutral
light
neutral
line in
light
light
line in
FAN
FAN
Match wire colors as shown: 
remove set screw
unplug connectors