Installation Guide

12
Installation For New
Construction
NOTE: Even with new construction, you can use the SheetLock™
installation method; however, ReVent can still be installed using a method
home builders would be more familiar with, as outlined in this section.
WARNING: Disconnect all AC Power Breakers or Fuses before attempting
to cut into your ceiling.
1.) Select a set of holding tabs, depending on the thickness of your sheetrock.
5
/8 in (1.6 cm)
holding tab
1
/2 in (1.3 cm)
holding tab
final securing tab
5
/8 in (1.6 cm)
holding tab
1
/2 in (1.3 cm)
holding tab
2.) Bend the holding tabs you selected outward.