Certifications 2
Page 3/10
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 03.02.2020 Revision: 03.02.2020version: 19
Trade nameREVELL EMAIL COLOR
No.01 Colourless glossy
No.02 Colourless matt
(Contd. of page 2)
49.4.23
CAS: 107-98-2
EINECS: 203-539-1
Reg.nr.: 01-2119457435-35
1-methoxypropan-2-ol
Flam. Liq. 3, H226
STOT SE 3, H336
12.5-20%
CAS: 108-65-6
EINECS: 203-603-9
Reg.nr.: 01-2119475791-29
2-methoxy-1-methylethyl acetate
Flam. Liq. 3, H226
1-2%
·
Additional information
*) Benzene content is less than 0.1% (EINECS-No. 200-753-7). It is P. Note
Contains no other ingredients (
≥
0,1%) that are classified as hazardous to health or the environment
according to the current knowledge of the supplier and must be mentioned in this section.
The wording of the listed risk phrases refer to section 16.
SECTION 4: First aid measures
·
4.1 Description of first aid measures
·
General information
Remove contaminated, saturated clothing immediately.
·
After inhalation
Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if
symptoms persist.
In case of unconsciousness bring patient into stable side position for transport.
·
After skin contact
Instantly wash with water and soap and rinse thoroughly.
If skin irritation continues, consult a doctor.
·
After eye contact
Rinse opened eye for several minutes under running water. If symptoms persist, consult doctor.
·
After swallowing
Do not induce vomiting; instantly call for medical help.
*
SECTION 5: Firefighting measures
·
5.1 Extinguishing media
·
Suitable extinguishing agents
CO2, sand, extinguishing powder. Do not use water.
·
For safety reasons unsuitable extinguishing agents
Water.
·
5.2 Special hazards arising from the substance or mixture
Fire will produce dense black smoke. Exposure to decomposition products may cause a health
hazards.
·
5.3 Advice for firefighters
·
Protective equipment:
Wear self-contained breathing apparatus.
·
Additional information
Cool closed containers exposed to fire with water.
Do not allow run-off from fire fighting to enter drains or water courses.
SECTION 6: Accidental release measures
·
6.1 Personal precautions, protective equipment and emergency procedures
Remove all sources of ignition. Provide adequate ventilation. Refer to protective measurer, listed in
sections 7 and 8.
·
6.2 Environmental precautions:
Do not allow product to enter into sewerage systems or water bodies.
Inform respective authorities in case of product reaches water or sewage systems.
(Contd. on page 4)