Charging Steps {detail)
The
Ex-1
battery charger features a 4 step charging process:
Step 1: Diagnostic Start Mode
Checks the battery voltage
to
make sure battery
connections
are
good
and the
battery is in a stable
condition
before beginning the charging process. Will
start
the
charging process
with
a gentle
"soft"
charge.
Step
2:
Primary Charge
Continues the Primary charging process, charges battery
to
90°/o
capacity.
Step
3:
Final Charge
Brings the charge level
to
1
00°/o.
Once
this
threshold
is
reached, the battery charger
will deliver small amounts
of
current
to
provide a safe, efficient charge and
limit
battery gassing.
Step
4:
Battery Maintain
Monitors the battery voltage
continuously
to
determine
if
a maintenance charge
should
be initiated.
If
the terminal voltage falls
below
approximately 6.4V {6V) and
12.8V {12V), the charger will start the Battery Maintain cycle until voltage reaches
approximately 7.2V {6V) and 14.4V {12V) and then
will
discontinue the charge cycle.
Maintain cycle
is
repeated indefinitely
to
keep the battery at full charge,
without
overcharging. Once connected and in
this
mode, the battery charger can be left
connected indefinitely.
Input Voltage AC:
Working Voltage AC:
Input
Current:
Efficiency:
Power:
Charging Voltage:
Charging Current:
Back Current Drain:
Charger Type:
Type
of
Batteries:
Battery Chemistries:
Battery Capacity:
Housing Protection:
Cooling:
Noise Level:
Dimensions {L x W x H):
Weight:
Approval:
120 VAC, 60Hz
110-130 VAC, 50-60Hz
1.2ARMS Max
82°/o
Approx.
68W Max
7.2V/14.4V
3500mA
<5mA
4 Step, Fully Automatic, Switch-Mode
6V
& 12V Lead-Acid
Wet, Gel,
MF
& AGM
12-70Ah, Maintains
All
Battery Sizes
IP65
Natural Convection
<50
dB
6.5 x 2.9 x 1.83 Inches
.53
Kg/1.17
Pounds
UL
for
US
and Canada