Operating instructions

Outgoing messages
20
If you record OGM 5 as outgoing message without incoming recording
(announcement only), your tiptel 345 pro will automatically switch to this OGM
as soon as the recording capacity for the current OGM with incoming recording
should be exhausted.
Recording OGMs from an external signal source
Professional OGMs can also be recorded from external signal sources (e. g. tape
deck) - via the audio input.
Select the desired OGM by pressing
the select button next to the OGM
symbol.
The selected OGM is displayed next to
the symbol on the bottom right side.
Press the button for the secondary
function.
The display shows the symbol for the
secondary function.
Keep OGM pressed. Wait until you hear a brief tone, the dis-
play shows a cassette symbol which in-
dicates the readiness to record via the
audio input.
Start the playback function at the
external signal source.
The display shows the duration of the
current recording in minutes and sec-
onds.
To stop the recording, release the
OGM button.
The display shows with incoming re-
cording and without incoming record-
ing.
Use the select button next to the
corresponding line, to determine
whether the OGM shall be available
with or without an option for an in-
coming recording.
The recording is complete and it will be
played back for test purposes. An OGM
without incoming recording is indicated
by just 1 signal tone. An OGM with in-
coming recording option is indicated by
2 signal tones.