RE5000S professional Solar Wireless Intruder Alarm System includes: 1 x Solar Wireless Siren and Strobe 1 x Control Unit 1 x Passive Infra Red Detector 1 x Magnetic Contact Detector 1 x Remote Control 1 x Power Supply INSTALLATION & OPERATING HANDBOOK PROFESSIONAL alarm systems
FOREWORD Your decision to purchase an RE5000S Remote Control Wireless Intruder Alarm System represents a major and sensible step towards total protection of your premises, its contents and its occupants. The RE5000S Wireless Intruder Alarm System complies with the requirements of BS 6799 Class 3 for Wire-free Intruder Alarm Systems. All components are designed and manufactured to provide a high standard of security protection and long, reliable service.
CONTENTS Page No. FOREWORD Inside Front Cover INTRODUCTION & OVERVIEW 2 EXTENDING THE RE5000S SYSTEM 2 PLANNING AND EXTENDING YOUR WIRELESS ALARM SYSTEM 4 CONTROL UNIT Indicators and Keypad Location Installation Back-up Battery 5 5 6 7 SYSTEM HOUSE CODE 7 REMOTE CONTROL(S) 8 SETTING THE CONTROL UNIT HOUSE CODE 8 Page No.
INTRODUCTION & OVERVIEW The RE5000S Alarm System is designed to allow flexibility in configuring and using the system. The Detectors can be set to operate on any one of 6 Zones, to give an instant alarm or a variable timed entry delay. There is no limit to the number of detectors per Zone. A normally closed, hard-wired Zone input is also available on Zone 6. Part Arm allows only selected detection Zones to be armed.
Control Unit in-line Mains adaptor Solar Wireless Siren & Strobe (incorporating rechargeable battery) Wireless Passive Infra Red Detector (RE5000P) Wireless Standard Magnetic Contact Detector (RE5000M) Control Unit with Communicator Wiring Interface Rechargeable Batteries (fitted in the Control Unit and the Siren & Strobe) Also included:Installation and operating manual Wireless Remote Control (RE5000R) RE5000S Professional Alarm System All necessary fixings Window warning stickers Detector and Rem
PLANNING AND EXTENDING YOUR WIRELESS ALARM SYSTEM For even greater protection you can install as many PIR’s and Magnetic Contact Detectors as and when you require. The RE5000S Alarm System is designed to give you protection for a two bedroomed house. Just add additional detectors where further protection is needed. Each property will have its own layout, the diagram shown is intended as a guide. PART ARM PLANNING YOUR INSTALLATION Protect either all of your home or just the areas you choose.
CONTROL UNIT INDICATORS AND KEYPAD View of Control Unit Indicators and Keypad LOCATION When choosing a suitable location for the Control Unit, the following points should be considered. 3. The Control Unit should be close to the entry/exit door but not visible from the door or windows. 1. Ensure that the Control Unit is within a protected area with the system Armed, ie: an intruder cannot reach the Control Unit without opening a protected door or being detected by a movement detector. 4.
INSTALLATION Remove the fixing bracket securing screw and slide the fixing bracket off of the keyhole slots at the top of the Control Unit. Hold the fixing bracket level in position on the wall and mark the 3 fixing bracket holes on the wall. Drill 3 x 4mm diameter fixing holes; fully insert the plastic wall plugs supplied and secure the bracket to the wall using the three fixing screws. proceed as below: 1. Select a suitable location for the Mains Adaptor (eg: a mains supply cupboard).
the terminals on your equipment proceed as follows: Unit for a period of approx. 8 hours and will automatically recharge on restoration of the supply. 1. To fit the Back-up Battery, connect the battery leads red to red (+) and black to black (-) and place the battery into the battery compartment. The wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red.
REMOTE CONTROL(S) One Remote Control Unit is supplied in the standard RE5000S package. However, additional Remote Control Unit(s) can be purchased separately, if required. The Remote Control Unit(s) are used to Arm and Disarm the System. The Remote Control Unit also incorporates a personal attack button. This sounds the alarm at any time whether the system is Armed or not. Just press and the alarm will sound.
The Control Unit will acknowledge the signal by bleeping twice and memorise the ‘House Code’ set in the Remote Control. The Zone LED’s 1-6 will now indicate the ‘House Code’ switch setting selected for each switch 1-6 in the Remote Control as follows:‘+’ = LED ‘ON’ ‘o’ = LED ‘FLASHING’ ‘-’ = LED ‘OFF’ 5. Once the ‘House Code’ has been set, press twice to exit programming mode.
WIRELESS PASSIVE INFRA RED DETECTOR(S) One Passive Infra Red Detector is supplied in the standard RE5000S package. However, additional Passive Infra Red Detectors can be purchased separately, if required. Passive Infra Red Detectors are designed to detect movement within a protected area. The Detector element detects differences in the infra red radiation when a person moves within the protected area. If movement is detected, a radio signal is transmitted to the Control Unit to activate the alarm. 3.
ENSURE THAT THE CONTROL UNIT IS STILL IN TEST MODE. 1. Remove the battery cover by sliding it down and pulling it forward. DO NOT USE A SCREW DRIVER. 6. Position the Detector on the locating pin and slide down, then fix the Detector to the wall bracket using the holding screw. 2. Using a ball-point pen, set the miniature switches 1-6 inclusive to the pre-determined House Code. 3. Determine the Zone on which each Detector is to operate and set miniature switches 7 and 8 to correspond to the required Zone.
FURTHER TEST: 1. When the battery cover is fitted, once again leave the protected area and ensure that no movement takes place for at least 60 seconds. and the appropriate Zone LED will flash for 3 seconds. This confirms that the ‘House Code’ and Zoning is correct. 2. Walk into the protected area. The Control Unit will emit a two-tone chime. Note: When the Detector is fully installed, ie. battery cover is refitted, the unit will not detect movement for approximately 60 seconds after each activation.
5. Hold the Contact Detector at the correct position on the door or window, then press and release the anti-tamper switch. Providing the Detector is within radio range of the Control Unit, the two-tone chime will be repeated, for another 3 seconds. When fitting the detector to a metal door or window, under exceptional circumstances, it may be necessary to space the Magnet/ Detector off the metal surface using a plastic or wooden spacer to achieve the necessary radio range. 6.
View of inside Solar Siren & Strobe The Solar Siren & Strobe contains a sophisticated radio receiver. However, reception of radio signals can be affected by the presence of metallic objects within the vicinity of the Solar Siren & Strobe. It is therefore important to mount the Solar Siren & Strobe a minimum distance of 1m radius away from any external or internal metalwork, ie. external drainpipes, gutters and internal radiators, mirrors etc.
Hinge the front cover locating tabs over the top edge of the backplate, push the base of the Siren cover into place and secure with the lower fixing screw. The Full Arm and Part Arm LED’s will illuminate and all the Zone LED’s will flash to indicate the system is in programming mode. IMPORTANT Note: If you make an error when entering your settings, press once to exit the programming function then enter the function number followed by and re-enter your correct settings.
The Zone LED’s 1-6 will indicate the new ‘House Code’ switch setting selected for each switch 1-6 as follows:‘+’ ‘o’ ‘-’ To change the setting, press the appropriate key to illuminate the associated Zone LED:- - LED ‘ON’ - LED ‘FLASHING’ - LED ‘OFF’ Press to memorise the ‘House Code’ setting and to revert to the Programming mode. Enter to memorise the setting and to revert to the Programming mode. 2. INSTANT/DELAY ZONE 4.
general use of the system to be via this second code (eg. for children, guests, cleaners etc) and to retain the Main User Access Code for your personal use in re-programming the system. To change the Main User Access Code:With the Control Unit in programming mode Enter . No Zone LED’s will be illuminated. Enter your new Access Code. The Zone LED’s 1-4 will illuminate as each digit is entered. Press to memorise the setting and to revert to Programming mode. 6.
9. EXIT DELAY TONE During the Exit delay period the Control Unit may be set to either remain silent or to give an intermittent bleep tone. With the Control Unit in Programming mode Enter . continuously jammed for more than 30 seconds the Control Unit sounder will emit a Pre Alarm series of rapid bleeps for 5 seconds.
thereby ensuring that the signal is correctly received. For full details of the setting and operation of the optional Medical Alert Pendant refer to the instructions supplied with the unit. To programme the Siren Code into the Control Unit, with the Control Unit in Programming mode Enter .
OPERATING INSTRUCTIONS IMPORTANT The System cannot be Armed, Part Armed or put into Test mode if any previous low battery or alarm indication has not been cleared, (indicated by any Zone LED’s flashing) or if a Magnetic Detector is open (indicated by the appropriate Zone LED’s illuminating steadily). When an attempt is made to Arm the system under any of these conditions the Control Unit will emit 3 rapid bleeps. For a low battery condition, replace the detector battery prior to clearing the indication.
When fully armed the Full Arm LED will be illuminated steadily. PART ARMING THE SYSTEM If you are remaining in the premises, you may arm all the Zones which have not been omitted, by selecting Part Arm. This will permit free access to the omitted Zone areas. The system may be set on ‘Part Arm’ either at the Control Unit or using a Remote Control Unit. If setting on ‘Part Arm’ at the Control Unit, you must first Enter your 4 digit access code (Main User or Second User Code) then press .
FIRE ALARM:- Press and hold the button on the Control Unit for 3 seconds. The Control Unit will initiate a full alarm. A special Fire Alarm tone will sound at the Control Unit and Zone 7 LED will flash. A Fire Alarm can also be initiated from an optional Smoke Detector ref RE5000SD. MEDICAL ALERT:- Press and hold the button on the Control Unit for 3 seconds. The Control Unit will initiate a full alarm. A special Medical Alert tone will be sounded at the Control Unit and Zone 8 LED will flash.
Second User Access code followed by Control Unit. at the Siren & Strobe fit a new 9V PP3 leak proof alkaline Initial Power-Up battery to ensure that the unit receives sufficient power until the solar panel can recharge the main battery completely. MAINTENANCE Your RE5000S Intruder Alarm System requires very little maintenance. However, a few simple tasks will ensure its continued reliability and operation. CONTROL UNIT The Control Unit requires no maintenance.
TROUBLE SHOOTING Symptom / Recommendation Control Unit will not arm. Control Unit emits 3 bleeps when trying to arm. 1. Magnetic Contact Detector ‘Open’ - Check Zone LED illuminated and close detector(s) on that Zone. If Detector cannot be closed, enter, then exit Programming mode to clear the indication. 2. Low battery in a Detector. Check Zone indicated, change battery and clear indication at Control Unit. 3. Alarm/low battery indicator not cleared.
TROUBLE SHOOTING Symptom / Recommendation Solar Siren and Strobe does not operate when system activated. 1. Incorrect Siren Code dip switch settings in Solar Siren and Strobe or Siren code incorrectly programmed into Control Unit. 2. Siren duration time timed-out before Control Unit Autostop time. 3. Disconnect rechargeable and power-up batteries. Cover solar panel and leave unit for 3-5 minutes. Re-connect the batteries and then remove the Solar panel cover. 4. Rechargeable battery low.
IMPORTANT NOTICE FOLLOWING ALARM INSTALLATION In order to comply with the Code of Practice on Noise from Intruder Alarms 1981 you should carry out the following procedures within 48 hours of the Intruder Alarm installation. 1. Notify your local police station in writing that an Intruder Alarm System has been installed, giving details of at least two persons who know the Access Code(s) or are in possession of a Remote Control Unit. 2. Ensure that all users are aware of the operating procedures. 3.
EXTENDING YOUR RE5000S PROFESSIONAL WIRELESS ALARM SYSTEM You may add additional Remote Controls, Standard Wireless Magnetic Contact Detectors and Wireless PIR Detectors etc, as required, to give additional protection where needed. The following accessories are also available to extend and enhance your system:- ADDITIONAL SOLAR WIRELESS SIREN & STROBE RE5000SS Additional Solar Wireless Siren & Strobes can be added to your RE5000S Professional Solar Wireless Alarm System to give a higher level of security.
EXTENDING YOUR RE5000S PROFESSIONAL WIRELESS ALARM SYSTEM Continued. WIRELESS SMOKE DETECTOR RE5000SD In the event of fire the battery operated Wireless Smoke Detector will send a security coded signal to your Control Unit which will activate your Alarm System. The Smoke Detector also has its own siren and when used with the RE5000S Wireless Alarm provides an exceptionally high level of safety to your home.
If you have a problem with your Alarm, or if you have an item that you feel requires replacement for whatever reason, please do not hesitate to call our Helpline on: 09062 777200 (Lines open 9.00am to 6.00pm, Monday to Friday. Calls charged at 25p per minute) We can solve most problems quickly over the phone. YOUR GUARANTEE This product (excluding Alkaline batteries) is guaranteed for one year from the date of purchase against faulty materials or workmanship. We will repair or replace any faulty product.
IMPORTANT – PLEASE REGISTER YOUR GUARANTEE WITHIN 14 DAYS OF PURCHASE Guarantee Registration To register your purchase and help us provide you with the latest information on system accessories and give the fastest possible service in the event of a problem, please take a minute to complete this registration and post it back to us, in the Freepost envelope provided. Don’t forget to keep your receipt safely, as you will need it in the event of a claim.
FREE ENTRY INTO PRIZE DRAW FOR OUR TO WIN A FANTASTIC PRIZE (See the enclosed Prize Draw Offer Sheet for the current offer, plus Prize Draw Rules) Either fill in your details overleaf and return the GUARANTEE REGISTRATION FORM WITH the ENCLOSED PRIZE DRAW OFFER SHEET within 14 days to: Response Electronics Plc Guarantee Registration Department FREEPOST KT4437 Epsom, Surrey KT19 9BR ALTERNATIVELY you can register your Guarantee online via www.responseplc.
RE5000S PROFESSIONAL SOLAR WIRELESS ALARM SYSTEM - SPECIFICATION Control Unit Wireless Passive Infra Red Detector Magnetic Contact Detector Order Code: RE5000P (with hard-wired inputs) Order Code: RE5000MHW Response Electronics Plc are Quality Assurance Registered to BS EN ISO9002 1994, by SGS Yarsley ICS.