Cross Reference Addendum
R7284U Universal Electronic Oil Primary
SELECTION GUIDE
Ignition Type
Universal Service
Part
R7184U Service Part
R7284 Direct
Service Part
Specications (Direct and Universal Parts to Left) Cross-Reference
Lockout Time
(sec.)
Valve On Delay
(sec.)
Blower Off Delay
(min.)
Alarm
Contacts*
Manual Trip Lever
w/ LED Indicator
Resideo Beckett Carlin
White-Rodgers
Interrupted R7284U1004
R7184U1004
15 0/15 0/2/4/6 Yes Yes
R7184U1004, R7184P1031, R7184P1049, R7184P1056,
R7184P1064, R7184P1072
7505P125M
50200-02S, 602000-02S, 6020002S015120, 6020002S030015,
6020002S030015, 6020002S030030, 6020002S030120,
6020002S030300, 6020002S030010
15 Yes Yes R7184A1026, R7184A1075, R7184A1000 7505A0000 40200-02S 669-640, 669-670
R7284B1024 15 15 Yes Yes R7184B1024, R7184B1032, R7184B1016 7505B1500
15 15 0.25 Yes Yes R7184P1080, R7184P1098 7505P1515
R7184U1012
30 0/15 0/2/4/6 Yes No R7184U1012
30 No R7184A1018, R7184A1034 42230-02S 669-440, 669-445, 669-470, 669-540
R7184U1020
45 0/15 0/2/4/6 Yes No R7184U1020
45 R7184A1042
Intermittent R7284U1004
R7184U1004 15 Yes
R8184G1294, R8184G1302, R8184G4066, R8184G4074,
R8184G4033, R8184G4090, R8184G1427, R8184G4058
7505A0000 668-601, 668-670
R7184U1012 30 R8184G1393, R8184G1302, R8184G4074, R8184G4033 668-501
R7184U1020 45
Yes
R8184G1286, R8184G1427, R8184G1458, R8184G4009,
R184G4025, R8184G4082, R8184G4108
48245-S
668-401, 668-0415, 668-430, 668-515
Yes 668-430
R8184M1051 R8184M1051 45 R8184M1002 668-441, 668-451, 668-454
* R7284 models require an alarm contact accessory module
L7224U Universal Electronic Aquastat
®
SELECTION GUIDE
Product Number
Fuel Low Limit High Limit Features and Functions
Gas Oil Operating Range, Low Limit Differential Temperature, Low Limit Operating Range, High Limit Differential Temperature, High Limit Switching Action Anticipator Setting Mounting
L7224U1002 • 110˚ to 220˚ F 10˚ to 25˚ F adj. 130˚ to 240˚ F 5˚ to 20˚ F adj. 3 SPST: High and Low Limit, Circulator 0.1 A V/H/F
REPLACEMENT SENSOR
Part Number Length (in.)
50001464-001 12
50001464-004 36
50001464-005 48
CROSS-REFERENCE GUIDE
OS Number Replaces Mounting Orientation High Limit High Limit Difference Low Limit
Low Limit
Difference
L7224U1002
L7124A1017, L7124A1025, L7224A1008, L7224A1016, L8124A1007, L8124A1015, L8124A1049, L8124A1098, L8124A1106, L8124A1114, L8124A1122, L8124A1130, L8124A1155 Well Mounted – Vertical 130˚ to 240˚ F 10˚ F 110˚ to 220˚ F 10˚ to 25˚ F
L7124C1005, L7224C1004, L8124C1003, L8124C1011, L8124C1029, L8124C1094, L8124C1102 Well Mounted – Horizontal 130˚ to 240˚ F 10˚ F 110˚ to 220˚ F 10˚ to 25˚ F
L7148A1019, L7248C1014, L8148A1009, L8148A1025, L8148A1033, L8148A1058, L8148A1066, L8148A1074, L8148A1082, L8148A1090, L8148A1116, L8148A1157 Well Mounted – Horizontal 180˚ to 220˚ F 15˚ F
L7148A1035, L7248C1006, L8148A1017, L8148A1065, L8148A1124, L8148A1140 Well Mounted – Horizontal 140˚ to 240˚ F
L7148A1050, L7248A1000, L8148A1157 Well Mounted – Vertical 180˚ to 220˚ F
L7248C1022 Flush Mounted – Vertical 140˚ to 240˚ F
L7224U Universal Electronic Aquastat
®
SELECTION GUIDE
Product Number CAD Cells (1) Lead Length (in.) Wire Termination Mounting Bracket Includes Tradeline Value
Replaces White-Rodgers Westwood
C554A1315 120320 30 Stripped Type B Tradeline
C554A1463 130367 60 2 Flag 1/4” QC Type R
A, B, E, J and P Mounting Brackets and Fuel
Line Adaptor
Super Tradeline
C554A1307, C554A1315, C554A1398, C554A1133, C554A1174,
C554A1372, C554C1570, C554A1216, C554A1927,
C554A1794
956 -154 TMK-60
C554A1794 130367 60 Stripped Type R E Mounting Bracket and Fuel Line Adaptor Tradeline C554A1307, C554A1927 956-11, 956-154 TMK-60
Notes:
*120320 replacement CAD cell 7.5 MA minimum sensitivity at 2’ candles.
*130367 high-sensitivity CAD cell 12 MA minimum sensitivity at 2’ candles.
1 48 inch lead wire


