Install Instructions
VR8245 AND VR8345 ELECTRONIC IGNITION GAS CONTROLS
© 2020 Resideo Technologies, Inc. All rights reserved.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.
www.resideo.com
Resideo Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
69-2013—04 M.S. Rev. 05-20 | Printed in United States
4. If voltage is not present, check control circuit for
pro-per operation.
5. If proper control circuit voltage is present, replace
gas control.
Instructions To The Homeowner
(For Your Safety, Read Before Operating)
WARNING
FIRE OR EXPLOSION HAZARD
CAN CAUSE PROPERTY DAMAGE, SEVERE
INJURY, OR DEATH
Follow these warnings exactly:
1. Pilot/main burner flame is lit automatically. Do
not light the pilot/main burner flame manually.
2. Before lighting appliance, smell around the
appliance for gas. Be sure to smell next to the
floor because LP gas is heavier than air.
3. IF YOU SMELL GAS:
• Turn off the gas supply at the appliance
service valve. On LP gas systems, turn off
gas supply at the gas tank.
• Do not light any appliances in the house.
• Do not touch electrical switches or use
phone.
• Leave the building and use a neighbor’s
phone to call your gas supplier.
• If you cannot reach your gas supplier, call
the fire department.
4. Do not force the gas control knob. Use only
your hand to push down or turn the gas
control knob. Never use any tools. If the gas
control knob will not operate by hand, call a
qualified service technician to replace the gas
control. Force or attempted repair can result in
a fire or explosion.
5. Call a qualified service technician to replace
the gas control if it has been flooded with
water.
6. Call a qualified service technician to replace
the gas control in the event of any physical
damage, tampering, bent terminals, missing or
broken parts, stripped threads, or evidence of
exposure to heat.
IMPORTANT:
Follow the operating instructions provided by
the manufacturer of your heating appliance.
The information below will be of assistance in a
typical gas control application, but the specific
controls used and the procedures outlined by
the manufacturer or your appliance may differ
and require special instructions.
To Turn On The Appliance
Stop: Read the warnings on page 8.
The pilot/main burner flame is lit automatically. Do not
attempt to manually light the pilot. If the appliance does
not turn on when the thermostat is set several degrees
above room temperature, follow these instructions:
1. Set the thermostat to its lowest setting to reset
the safety control.
2. Disconnect all electric power to the appliance.
3. Remove the gas control access panel.
4. Push in the gas control knob slightly and turn
clockwise to OFF.
5. Wait five minutes to clear out any unburned gas. If
you then smell gas, STOP! Follow step 3 of the
Warning in the Instructions To The Homeowner
section. If you do not smell gas, continue with the
next step.
6. Turn the gas control knob counterclockwise to
ON.
7. Replace the gas control access panel.
8. Reconnect all electric power to the appliance.
9. Set the thermostat to the desired setting.
10. If the appliance does not turn on, set the gas con-
trol knob to OFF and contact a qualified service
technician for assistance.
Turning Off The Appliance
VACATION SHUTDOWN—Set the thermostat to the
desired room temperature while you are away.
COMPLETE SHUTDOWN—Push in the gas control knob
slightly and turn clockwise to OFF. Do not force.
Appliance will completely shut off. Follow the
Instructions to the Homeowner above to resume normal
operation.