TO TURN ON FURNACE
STOP: Read the Warnings Above
1. The lighting sequence on this appliance is auto-
matic; DO NOT ATTEMPT TO MANUALLY LIGHT
THE PILOT.
2. If the furnace does not come on when the thermo-
stat is set several degrees above room tempera-
ture, set the thermostat to the bottom of its range
to reset safety control.
3. Remove the burner access panel if provided on
your appliance.
4. Turn the gas valve knob (Fig. 4) clockwise to
OFF.
5. Wait five minutes to allow any gas in the combus-
tion chamber to vent. If you then smell gas in the
appliance area or near the floor in an LP installa-
tion, immediately shut off the manual valve in the
gas piping to the appliance or, ON LP, AT THE
TANK. Don’t touch any electrical switch or use the
phone. Do not try to light any appliance. LEAVE
THE BUILDING and call your gas supplier. If your
gas supplier cannot be reached, call the fire
department. Failure to do so may result in fire or
explosion.
6. If you don’t smell gas, turn knob on gas control
counterclockwise to ON.
7. Replace burner access panel.
8. Reset thermostat to desired temperature.
9. If appliance will not operate, turn the gas control
knob to OFF and contact a qualified service tech-
nician for assistance.
Turning Off the Appliance
Turn gas control knob clockwise to OFF.