Brochure

Product Number CAD Cells (1) Lead Lengt (in.) Wire Termination Mounting Bracket Includes Tradeline Value Replaces
C554A1315 120320 30 Stripped Type B Tradeline
C554A1463 130367 60 2 flag 1/4 in. QC Type R
A, B, E, J and P mounting brackets and fuel
line adaptor
Super Tradeline
C554A1307, C554A1315,
C554A1398, C554A1133,
C554A1174, C554A1372,
C554C1570, C554A1216,
C554A1927, C554A1794
C554A1794 130367 60 Stripped Type R
Type “E” mounting bracket and fuel line
adaptor
Tradeline C554A1307, C554A1927
CAD Cell Selection Guide
Size Features and Functions Notes Cross Reference
Product Number
Switch
Configuration
Capillary Length (in.) Insulation Depth (in.)
Spud Size —
14 NPT (in.)
Manual
Reset
Operating Temperature
Range (˚F)
Factory Stop
(˚F)
Differential
Temperature (˚F)
Electrical
Ratings (3)
Mounting (2) Notes OEM Product Number
L4006A1009
SPST — N.C.
(Break on Rise)
1.5 1/2 100 – 240 5 Fixed A H/V
L4006A1017 1.5 1/2 100 – 240 5 – 30 A H/V
L4080B, L4080D Families, L4006A1058,
L4006A1827, L4006A2015
L4006A1132 3 3/4 100 – 240 160 5 Fixed A H/V L4006A2023
L4006A1678 3 100 – 240 5 – 30 A H/V
L4006A1959 3 40 – 180 2 Fixed B H/V
L4006A1967 1.5 1/2 100 – 240 5 – 30 A H/V
L4006A2007 3 100 – 240 5 – 30 A H/V
L4006A2148 3 100 – 200 5 – 30 A H/V
L4006E1067 3 Yes 130 – 270 A H/V
L4006E1091, L4006E1109, L4006E1117,
L4006E1125, L4006E1133
L4006H1004 1.5 100 – 240 240 D H/V
Bracket for strap-on mounting
and heat-conductive compound.
L4008E1156 66 Yes 130 – 270 A H/V L4008E1040, L4008E1248, L4008E1321
L4008E1305 66 Yes 100 – 240 A H/V L4008E1271, L4008E1313
L4008E1313 66 Yes 100 – 240 A H/V
L4008E1347 66 Yes 40 – 180 A H/V
L4006B1007
SPST — N.O.
(Make on Rise)
1.5 1/2 100 – 240 5 Fixed A H/V
L4006B1155 3 100 – 240 5 – 30 A H/V L4006B1189
L4006B1163 3 100 – 240 5 – 30 A H/V
L6006A1004
SPDT
1/2 100 – 240 5 A H/V
L6006A1012 1.5 1/2 100 – 240 5 – 30 A H/V
L6006A1160, L6006A1269, L6006A1301,
L6006A1327, L6006A1335
L6006A1145 3 100 – 240 240 5 – 30 A H
L6006A1244 3 100 – 240 5 – 30 A H/V
L6006C1018 65 – 200 5 – 30 A H/V/SMT L6006C1034, L6006C1059
L6008A1093 66 -30 – 70 5 – 30 A H/V L6008A1010
L6008A1192 66 100 – 240 240 5 – 30 A H/V
L6008A1242 66 100 – 200 5 – 30 A H/V
Notes:
120320 Replacement Cad Cell. 7.5 mA minimum sensitivity at 2 ft. candles.
130367 High Sensitivity CAD Cell 12 MA minimum sensitivity at 2 ft. candles.
Single-Function Aquastat
®
Selection/Cross-Reference Guide
For additional cross-reference information, see
www.customer.honeywell.com
or call 1-800-328-5111.
63-9661
October 2006
© 2006 Honeywell International, Inc.
Part Number Spud Length (in.) Insertion Depth (in.)
123869A 1/2 1 – 1/2
123872A 1/2 3
123870A 3/4 1 – 1/2
138871B 3/4 1 – 1/2
138134E 3/4 2 – 1/4
123871A 3/4 3
Thermowells Selection Guide
(2) Mounting H/V Horizontal or Vertical Mounting
H Horizontal Mounting
SMT Mount using 1/4 in. NPT female threads or surface mount through base of case
(3) Electrical Ratings
A Millivolt: 0.25 A @ 0.25 to 12 Vdc; AFL: 8A @ 120 Vac|5.1A @ 240 Vac ALR: 48A @ 120 Vac|30.6A @ 240 Vac
D Millivolt: 0.25 A @ 0.25 to 12 Vdc; AFL: 1.3A @ 240 Vac|8A @ 120 Vac; ALR: 48A @ 120 Vac|30.6A @ 240 Vac
B AFL: 2.6 A @ 120 Vacl1.3 A @ 240 Vac; ALR: 15.6 A @ 120 Vacl7.8 A @ 240 Vac
Part Number Length (in.)
0001464-001/B 12
0001464-004/B 36
0001464-005/B 48
Single Function Electronic Aquastat
®
Replacement Sensors