Submittal Sheet

AM-1 Series
LEAD FREE THERMOSTATIC MIXING VALVES
SUBMITTAL SHEET
Job Name
Engineer
Mechanical Contractor
Contractor’s P.O. No.
Representative
Notes
Model(s)
Qty.
Notes
Qty.
Notes
Approval
Service
Tag No.
APPLICATION
The Honeywell AM-1 series accurately adjusts, maintains,
and limits the hot water temperature to a desired setting
selected by the user. By installing a Honeywell AM-1 mixing
valve, raising water heater storage temperature setting, and
limiting mixed outlet water temperature to a safe
temperature, more usable hot water is available.
SPECIFICATIONS
Design: Straight-Through (hot and cold at the same level)
Maximum Pressure: 150 psi (1034 kPa)
Certifications: ASSE, CSA and IAPMO listed
Patent Information: U.S. Patent No. 6,079,625
Warranty: 1 year limited warranty
MATERIALS
Body: Teflon®-Coated, Nickle-Plated Low Lead Brass*
Temperature Gauge Adapter/Thermowell: Low Lead Brass
Shuttle: Teflon-Coated Low Lead Brass*
O-Rings: EPDM Rubber
Teflon® is a registered trademark of DuPont or its affiliates.
*Lead Free Plumbing Code Compliance: The wettable
surfaces of lead free models contain less than 0.25% of
lead by weighted average.
DI
MENSIONS
Model Number
Pipe
Size
Operating
Temp.
CV
ASSE
Certs.
Dimensions
Inch
A
B
NPT
AM100-1LF
1/2”
70°F - 145°F
3.2
1017
5.8
2.7
AM101-1LF
3/4”
70°F - 145°F
3.8
1017
5.8
2.7
AM102-1LF
1”
70°F - 145°F
4.3
1017
5.8
2.7
AM100C-1LF
1/2”
70°F - 120°F
3.2
1017
5.8
2.7
AM101C-1LF
3/4”
70°F - 120°F
3.8
1017
5.8
2.7
AM102C-1LF
1”
70°F - 120°F
4.3
1017
5.8
2.7
Union Sweat
AM100-US-1LF
1/2”
70°F - 145°F
3.9
1017
5.4
2.8
AM101-US-1LF
3/4”
70°F - 145°F
3.9
1017
5.6
2.9
AM102-US-1LF
1”
70°F - 145°F
3.9
1017
6.3
3.7
AM100C-US-1LF
1/2”
70°F - 120°F
3.9
1017
5.4
2.8
AM101C-US-1LF
3/4”
70°F - 120°F
3.9
1017
5.6
2.9
AM102C-US-1LF
1”
70°F - 120°F
3.9
1017
6.3
3.7
AM100C1070-US-1LF 1/2” 70°F - 120°F
1.8
1017,
1070
5.4
2.8
4.6
AM101C1070-US-1LF 3/4” 70°F - 120°F
1.8
1017,
1070
5.6
2.9
4.9
AM102C1070-US-1LF 3/4” 70°F - 120°F
1.8
1017,
1070
6.3
3.7
6.5