User manual

ANT AZIM, ANT ELEV, ANT POL
These alarm messages indicate that an error has been detected for the axis
referenced in the alarm message. When one of these alarms is detected, the axis
is disabled. Go to RESET mode (section 4.5) to view the actual fault condition
which was detected and to clear the fault.
A Reset mode JAMMED indication may mean that the drive breaker is open.
This can occur if simultaneous movement is enabled, and the total current draw
from both motors exceeds 8 amps. Reset the breaker by pressing it back into
place, and disable Simultaneous AZ/EL movement via CONFIG mode. See
Section 4.10.2
NOTE: The following alarm conditions are cleared by going into CONFIG
mode and re-initializing the applicable CONFIG mode items. Access to
certain items is controlled by other CONFIG mode items - these controlling
items can sometimes make it difficult to clear a CONFIG mode data related
alarm. Please review the explanation of the role of these controlling
CONFIG mode items in section 2.4.
AZIM COUNT, ELEV COUNT
The internal position count has been corrupted. Manually find a satellite and go
into RE-SYNC mode to update positions. See Section 4.7
AZIM SLOW SPEED, ELEV SLOW SPEED
The code entered by the user for the azimuth or elevation slow speed has been
corrupted. Go to the corresponding speed mode and reenter the slow speed code.
See Section 4.8
AUTOPOL CONFIG DATA
The user has the option to configure the system for AutoPol ON or OFF, and to
denote a HI or LO level for the vertical polarization. If either of these values is
corrupted, this error will appear. Go to CONFIG mode and reenter the correct
values. See Section 4.10.1
SIMULTANEOUS AZIM/ELEV
This error indicates that the value for the Simultaneous Az/El Enable CONFIG
mode item has been corrupted. See section 4.10.2.
GEO POSITION
The checksum associated with the GEO COUNT value does not agree with geo
position in memory. Move the antenna to the proper GEO POSITION and
reenter the GEO ELEV POSITION in the CONFIG mode. Section 4.10.4