Operating instructions
Prodelin 3.8m Antenna Installation Kit 
29
7 Installation Checklist 
Before the installation, the following items should be addressed.... 
1.  Fused AC power with a local disconnect must be present at the antenna pad. The installation should 
conform to the NEC (National Electric Code) or any other applicable codes. Please refer to section 2 -
AC Power. The user is responsible for getting the AC power to the interface box - make provisions 
for any conduit or fittings which may be needed. 
2.  The installer must obtain and route the RC2000 to interface box interconnect cable. The RC2000 is 
designed for rack mounting indoors and can be powered by either 110 or 220/240 VAC. Please refer 
to section 3 for the specification of the interface cable. The user is responsible for any conduit or 
fittings required to route the interface cable to the interface box. 
3.  The RC2000C Az/El Inclined Orbit Satellite Tracking Antenna Controller requires an analog voltage 
input which is proportional to the satellite signal strength. The range of the AGC input voltage is 0 to 
10 volts. The RC2000 can accept two channels of AGC signal strength information and has gain and 
offset pots for each channel. This allows the RC2000 to work with any analog voltage which swings 
over any part of the 0 to 10 volt input range. The controller can be configured via software to accept 
negative polarity AGC inputs (i.e. a strong received signal corresponds to a smaller analog voltage). 
8 Tools and Materials Required For Installation 
•  Wiring Tools: wire cutters, wire stripper, crimp connector crimp tool. 
•  Heat gun or a lighter for use with heat shrink tubing. 
•  Hack saw for cutting liquid tight steel reinforced conduit. 
•  A fine straight bladed screwdriver for use with the AGC GAIN and OFFSET pots and the screw 
terminals on the circuit board in the interface box (tip 0.1” inch wide x .03” thick). A jewelers screw 
driver set may include these sizes. 
•  Phillips and straight bladed screwdrivers for gaining access to the interface box , the terminal boxes on 
the sensors, limit switches, and motors. 
•  A 12” Crescent wrench for working with the conduit fittings. 
•  Channel Lock pliers for working with conduit fittings. A regular set of pliers for use with the 3M 
Scotchlok connectors. 
9 Attachments 
Pulse Sensor Data Sheet (Dart CF-H1 or Powermation DTK-056M1 
Limit Switch Data Sheet (Elevation Limit Switch - Gemco 2006-402L60C, Azimuth Limit Switch - 2006-
402L30C) 
A Note 
Thank you for your support of our products. We appreciate your comments. If you find errors or 
omissions in this manual or any deficiencies in our products please contact us. 
Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas 66218-9680 • USA 
Phone: 913/422-0210 • Fax: 913/422-0211 • E-mail: support@researchconcepts.com
Website: www.researchconcepts.com