F31-C user manual

4. Data monitoring shows the
4.1. system status and detection results. The
laser equipment is initialized after power-on for about 15s and starts to enter the
detection state. According to the parameters set by the user, it continuously detects whether
there is an object in the target area. After the device is powered on, it will automatically start
uploading laser cloud point data, regional detection results, and system working status.
The content of the data monitoring interface includes the current system status display,
monitoring enable setting, input, and output status display, current working area group
display, laser cloud point display mode, mouse position information, and outline display area
group selection.
The current system status display includes "status code" and "monitoring status". The
status code is the internal detection status of the device. When the output is "E00", it means
that the system is running normally. The monitoring state is the data transmission state
between the host computer and the radar device, including three states: "monitoring", "stop
monitoring" and "communication abnormal". The "communication abnormal" state may be
an abnormal serial connection or abnormal closing of the serial port. Repair by reconnecting
the serial port or reopening the serial port.
The monitoring enables setting can set whether the current monitoring data is
uploaded or not. When “Stop Monitoring” is clicked, the monitoring data will stop uploading,
and the cloud point data and contour data in the host computer will be stopped from
updating.
The input and output status display includes four inputs and three outputs. The four-
way input selects the current working area group, and the three-way output corresponds to
the detection status of the different levels of each area group. When the current area is
triggered, the corresponding status indicator will display red. If it is not triggered, the
corresponding status indicator will display green.
The current work area group is the work area group switched by the four input states
detected by the current device. The detection result is based on the outline set by the current
working area group.
The laser cloud point display mode can be switched between "point" and "line".
The displayed content of the mouse position information includes "coordinate position"
and "angle position", where the coordinate position is the position in the coordinate system
after converting the scanning angle and scanning distance, and the angular position directly
displays the corresponding position of the current mouse in the radar scanning range Angle
and distance, except angle, the unit of position information is cm.
Outline display target area group selection, only the current work area group is
displayed after it is turned on by default. When the user selects an area group different from