Operation Manual
3. Operang Machine
Pre-use Checks:
1. Check oil level (refer to Maintenance secon).
2. Check condion of cuer blocks and ghtness of cuer block bolts (refer to Maintenance
secon).
3. Check power supply is properly earthed.
4. Check that power cord is undamaged and plug is not loose (also applies for extension leads).
Warm Up:
In cold weather, warm up unit for 60 seconds to ensure hydraulic oil reaches proper viscosity.
Pull trigger and repeat cut cycle without material 15-20 mes.
Stopper Adjustment:
Adjustable stopper must be set in correct posion dependent on size of rebar.
1. Insert rebar into U-shaped support.
2. Keeping rebar at 90⁰ to machine, screw in stopper unl it is just touching the rebar.
Cung Procedure:
1. Insert rebar between stopper and front cuer block, making sure it is properly seated in
U-shaped support.
2. Pull and hold trigger while cuer rod advances and fully cuts rebar.
3. Release trigger only once rebar has been fully cut to allow cuer rod to retract.
Note: Power will be compromised if hydraulic oil exceeds 70˚C. Allow machine to cool before
resuming operaon.
4. Maintenance
Cuer Blocks:
Check cuer blocks for damage before each use. If cuer block is damaged, replace block before
next use as per following diagram:
Check cuer block bolts for ghtness before each use. Use protecve gloves when handling
cuer blocks as edges are very sharp.
Ensure cuer block with
at edges installed here.
Ensure cuer
block with
rounded edges
installed here.
Fix longer cuer block bolt pair here
Fix shorter cuer block bolt pair here