Operation Manual

Brush Caps
Motor Housing
Lubricaon:
Lubricant shall be checked every 2 months for heavy usage or when loss of power is experienced.
Always use approved lubricant with high corrosion and fricon resistance properes.
Apply lubricant via grease gun to lubricant hole to ensure lubricant chamber remains full.
Lubricant Hole
6. Maintenance
Always ensure power is disconnected before performing maintenance.
Cleaning:
Always wear gloves to protect hands from metal splinters when cleaning.
Wipe or brush away all dust and metal lings (can use compressed air).
Carbon Brushes:
Inspect carbon brushes monthly. Worn brushes will result in power loss and cause irreparable
damage to the armature’s commutator. Check brushes immediately if a loss of power or electrical
fault is experienced.
Replacing Carbon Brushes:
1. Open the access side panel and locate the motor housing(s) with black lid.
2. Locate the brush caps on both sides near the top of the motor housing(s).
3. Open the brush caps with a screwdriver and remove carbon brushes from the machine.
4. Inspect the carbon brushes and replace where worn or damaged.
5. Reinstall new carbon brushes and brush caps securely.
6. Replace access side panel.