Operation Manual
Working Temperature -10˚C - +45˚C
Humidity <90% RH
Storage Temperature -20˚C - +65˚C
Elevaon < 100m
Environment Interior, waterproof, non-corrosive, non-ammable
4. Operang Machine
General notes:
Machine is equipped with an emergency stop buon.
Ensure pedal switch cords are securely fastened to inputs (if pedal switch required).
Always ensure point 1 angle is set at least 5 degrees higher than point 2 angle.
Ensure angle control dials are securely fastened.
Wait unl bending cycle is completed before starng new cycle.
If pedal switches are not required, press the start switch to bend to point 1 angle.
Pre-use Checks
1. Check power supply is properly earthed.
2. Check that power cord is undamaged and plug is not loose (also applies for extension leads).
Bending Procedure
1. Secure required xed bending pin and gyre bending pin combinaon as per table below.
2. Modify adjustment block to suit required bar size.
3. Securely fasten pedal switch cords to machine inputs (if required).
4. Connect to power source and observe power indicator light on machine face indicang
machine is ready for use.
5. Adjust point 1 and point 2 angle control dials to required angles ensuring point 1 angle is set
at least 5 degrees higher than point 2 angle. Securely fasten angle control dial once required
angles are set.
6. Stand well clear of machine (opposite direcon of bend).
7. Press the pedal switch connected to pedal switch point 1 input to bend to point 1 angle.
Note: Pressing the start switch will also bend to point 1 angle.
8. Press the pedal switch connected to pedal switch point 2 input to bend to point 2 angle.
9. Bender/cuer model also has pedal switch point 3 input to operate cuer (see Addional
Instrucons for Rebar Cuer secon).
5. Working Condions
Do not use or store machine outside of environmental condions below:
Fixed Bending Pin Gyre Bending Pin
ø80 ø115
ø105 ø85
Fixed Bending Pin Gyre Bending Pin
ø80 ø165
ø120 ø110
ø140 ø75
CRB-25/CRBC-25 CRB-32/CRBC-32