Installation Instructions
4.
5.
6 — Renusol ConSole · EN · 04/2011
A
A
A
B
BBB
C
C
D
E
H
G
F
ASSEMBLY
Assembling optional extension rails
end clamps
The optional extension rail should be
assembled on the slotted hole of the U
profile on the upper side of the ConSole.
Only use the screws, washers and nuts
supplied for fastening the installation.
Note:
The extension rail is only for
optimal assembly of the PV module on the
corresponding ConSoles.
Assembly step 1:
Now fasten the U profiles to the module.
Ensure that the slotted hole is on the
higher side of the ConSole and the smaller
round holes are on lower side.
Only ever use the fastening material sup-
plied.
Tighten the M6 screws with a maximum
torque of 10 Nm.
Assembly step 2:
The cabling of the PV modules should be
carried out by trained specialists.
Assembly step 3:
Lay the PV module symmetrically onto the
ConSole. When seated correctly, the clips
on the U profiles prevent from module
from slipping.
Important!
Regarding lightening, advice from specialist
companies is generally recommended. It
should be explained in the planning phase
of the PV installation on a building as
to what requirements are stipulated here
by the property insurer on the subject
of lightening and overvoltage protection.
The notes and regulations from the manu-
facturer of the modules and inverers should
be observed when carrying out (functional)
earthing.
Assembling the U profiles onto the PV module
OPTIONAL EXTENSION RAILS
Section A-A E PV module
F Hexagon screw M6 x 20 mm
G Washer
H Self locking nut M6
A ConSole
B U prole
C Extension rail
D Module frame
Self locking nut M6
Washer
U-Prol
Hexagon screw
M6 x 20 mm
Elongated hole
Round hole
Module frame