Installation Instructions

1.
4 — Renusol ConSole · EN · 04/2011
E
D
B
A
25°
A
min, innen
E
min, innen
E
C
Decide on the correct ConSole for the
module
First measure the distance "d" of the
assembly boreholes on the rear of the
module. Then calculate based on the table
which ConSole fits the width of the
module.
Indicate any extension rails required as a
separate position in the order.
If there are several possibilities, select the
ConSole that best suits the length of the
current module.
Measurement "A" of the ConSole should
correspond roughly to the length of the
module. Overlapping modules require more
ballast due to the larger area exposed to
the wind.
Always select the ConSole on which the
module surface overlaps the assembly edge
of the ConSole as little as possible. The
maximum overlap of length "A" per side
should not be over 12 cm.
ASSEMBLY PREPARATION
Recommended measurement of ConSole/PV module
Table for calculating the
suitable combination ConSole/PV module
Explanatory views
of the ConSole dimensions
PV module bottom view
X
= only with extension rail
d
Hole spacing
d = mm
ConSole
4.1 4.2 5.2 6.2
661 700
701 720
721 780
781 840
X
841 850
X
851 894
895 910
9111014
1015−1085
XXX
Measurement
A
mm
B
mm
C
mm
D
mm
E
mm
A
min, interior
x E
min, interior
mm
Installation surface
Building protection mat
mm
ConSole 4.1 1680 840 400 50 740 1300 x 400 0,62 cca. 1400 x 500
ConSole 4.2 1240 1090 530 50 960 890 x 490 0,47 cca. 1000 x 700
ConSole 5.2 1520 1080 500 40 960 1140 x 630 0,76 cca. 1300 x 700
ConSole 6.2 1740 1070 500 50 970 1380 x 630 0,84 cca. 1500 x 700