Instruction Manual
6
3
2
5 4
1
Display Features:
1. Messages Queued
2. Number of Connected Devices
3. Mobile Signal Strength
4. Messages Sent
5. Server Time
Feature Descriptions:
The module features a number of switch sensors which detect the trap status:
Item 1. Messages Queued
This is the number of messages from the sensors that are waiting to be sent to
the server. An attempt to send the messages to the server is made every minute.
After three attempts if the Control Panel could not connect to the server it will not
make any further attempts to contact the server for one hour. Messages received
during this hour will be entered on the queue.
Item 2. Number of Connected Devices
This is the number of sensors that are connected to the Control panel. The
Control Panel will expect regular data from these devices. If the sensors fail to
connect for 3 hours then this number will decrease.
Item 3. Mobile Signal Strength
This is an indicative value of the strength of the mobile signal. If there is no
connection then the telephone symbol will be flashing.
Item 4. Messages Sent
This is the number of messages from the sensors that have been sent to the
server. NOTE: If more than 1000 messages have been sent then the S- will
become S+ in this field.
Item 5. Server Time
This is always set to Greenwich Mean Time (GMT+00) and so does not change
for daylight saving time.