Full Product Manual
Table Of Contents
Troubleshooting
26
Troubleshooting
Indicator & Alarm Potential Issue Solution
Alarm beeps
Input voltage is below 11V. Keep input voltage above 11V.
Input voltage is above 16.0V. Keep input voltage below 16.0V.
Fault LED lit, long
beeping alarm
sound, and inverter
shutdown
Input voltage is below 10V. Keep input voltage above 10V.
Input voltage is above 16.5V. Keep input voltage below 16.5V.
Inverter overheats
Allow inverter to cool down.
Check for adequate ventilation.
Reduce the load on the inverter.
Operating equipment draws too
much power
Use a higher wattage inverter or
use a lower powered device.
Inverter is short circuited
Disconnect the inverter and turn
off the ON/OFF Switch to reset.
Yellow LED lit and
Inverter shut down
GFCI tripped
Disconnect appliances and turn
off the ON/OFF Switch to reset.