LED Overview
LED Status Alarm
Protection &
Alarm
Inverter Status
Fault LED in
solid red
Long
steady
beeping
sound
Overtemperature
protection
No output from the inverter.
Undervoltage
shutdown
No output from the inverter.
Overload
protection
No output from the inverter
output side. After 5s, the inverter
automatically restarts. After five times
of failed restart, the inverter needs to
be restored by manually turning it on.
Fault LED off
No sound
Short circuit
protection
No output from the inverter
output side. After 5s, the inverter
automatically restarts. After five times
of failed restart, the inverter needs to
be restored by manually turning it on.
Power LED in
solid green and
fault LED off
Beeping
sound
Undervoltage
alarm
Constant output from the inverter.
Power LED in
solid green
No sound
Recovery from
undervoltage
Normal output from the inverter output
side.
GFCI LED in
solid yellow
No sound GFCI protection
1. No output from the inverter output
side.
2. Please disconnect appliances
and turn off the ON/OFF switch to
reset, then try to connect different
appliances separately and see
if the yellow LED of the inverter
is always on. If not, it indicates a
current leakage problem on the
appliance. If it's always on, please
contact Renogy to deal with it.