Full Product Manual

Product Overview
08
1000W Inverter
N G L
7
8
6
51
AC Side View
432
No. Part Description
1
High Output AC
Terminals
Connect to 115V AC devices operating at higher
than 15 A or distributed wiring with multiple AC
outlets.
Remove the two screws on the protective cover to
access the terminals.
Terminal layout (facing the front panel)
z
Left: Neutral (N)
z
Middle: Ground (G)
z
Right: Live (L)
Note that Neutral and Ground are bonded inside.
2 Power LED (Green) Indicates the operation status of the inverter.
3 GFCI LED (Yellow)
Indicates that the ground fault circuit has been
interrupted.
In such case, restart the inverter.
4 Fault LED (Red)
Indicates that the inverter shuts down due to
overheating, overload, undervoltage, or overvoltage.
Solution: Immediately turn off all AC appliances.
Allow the inverter to cool before continuing. Make
sure that the ventilation vents are not blocked.
If an inverter shutdown was preceded by a
buzzing sound, there may be an excessive load in
combination with low voltage or a cable problem.
700W Inverter 1000W Inverter 2000W or 3000W Inverter