Renogy Pure Sine Wave Inverter 12V 700W/1000W/2000W/3000W USER MANUAL VERSION A2
Applicability The user manual applies to the following products: z 700W 12V Pure Sine Wave Inverter (RNG-INVT-700-12V-P2) z 1000W 12V Pure Sine Wave Inverter (RNG-INVT-1000-12V-P2) z 2000W 12V Pure Sine Wave Inverter (RNG-INVT-2000-12V-P2) z 3000W 12V Pure Sine Wave Inverter (RNG-INVT-3000-12V-P2) Disclaimer z Renogy ensures the accuracy, sufficiency, and the applicability of information in the user manual at the time of printing due to continual product improvements that may occur.
Table of Contents Important Safety Information .......................................................................................................... 01 Symbols Used .......................................................................................................................... 01 General Safety Information ...................................................................................................... 01 Introduction ......................................................................
1000W Inverter ........................................................................................................................ 27 2000W Inverter ........................................................................................................................ 28 3000W Inverter ........................................................................................................................ 28 Specifications .................................................................................
Important Safety Information Symbols Used General Safety Information Important Safety Information The user manual provides important installation, operation, and maintenance instructions for 12V 700W/1000W/2000W/3000W Pure Sine Wave Inverter. Please read the user manual carefully before installation and operation and save it for future reference.
Important Safety Information Symbols Used General Safety Information z Do not let the positive (+) and negative (-) terminals of the battery touch each other. Use only deep-cycle sealed lead-acid, flooded, gel, or lithium batteries. z Risk of explosion! Never install the inverter in a sealed enclosure with flooded batteries! Do not install in a confined area where battery gases can accumulate. z Be careful when working with large lead acid batteries.
Introduction General Information Key Features Pure Sine Wave Introduction General Information Renogy 12V 700W/1000W/2000W/3000W Pure Sine Wave Inverter (hereinafter referred to as inverter) is perfect for most off-grid systems, whether for a van, semi-trucks, fifth wheels, cabin, or any remote location needing power. The inverter converts DC Power stored in batteries into usable AC Power for appliances.
Introduction General Information Key Features Pure Sine Wave Pure Sine Wave The inverter outputs a pure sine wave similar to the waveform of the grid power. In a pure sine wave, the voltage rises and falls in a smooth fashion with very low harmonic distortion and cleaner utility-like power. Pure Sine Waveform 200 Amplitude (Volts) 150 100 50 0 -50 -100 -150 -200 -0.02 -0.015 -0.01 -0.005 0 0.005 0.01 0.015 0.
Package Contents Package Contents 12V Pure Sine Wave Inverter x 1 User Manual x 1 Renogy Pure Sine Wave Inverter 12V 700W/1000W/2000W/3000W VERSION A2 USER MANUAL Wired Remote Control x 1 ON RJ11 Network Cable (5m) x 1 ERR RMS-P2 Cable x 2 z 700W Inverter (RNG-INVT-700-12V-P2): 6 AWG @ 3 ft z 1000W Inverter (RNG-INVT-100012V-P2): 4 AWG @ 3 ft z 2000W Inverter (RNG-INVT-200012V-P2): 1/0 AWG @ 3 ft z 3000W Inverter (RNG-INVT-300012V-P2): Not included 05
Product Overview 700W Inverter 1000W Inverter 2000W or 3000W Inverter Product Overview 700W Inverter 1 7 AC Side View No. 2 3 4 6 Part 5 Description 1 Power LED (Green) Indicates the operation status of the inverter. 2 GFCI LED (Yellow) Indicates that the ground fault circuit has been interrupted. In such case, restart the inverter. Indicates that the inverter shuts down due to overheating, overload, undervoltage, or overvoltage.
Product Overview 700W Inverter 1000W Inverter 1 DC Side View No. 2000W or 3000W Inverter 2 3 4 Part No.
Product Overview 700W Inverter 1000W Inverter 2000W or 3000W Inverter 1000W Inverter 1 N G 2 4 5 L 8 AC Side View No. 3 7 Part 6 Description Connect to 115V AC devices operating at higher than 15 A or distributed wiring with multiple AC outlets. 1 High Output AC Terminals Remove the two screws on the protective cover to access the terminals.
Product Overview 700W Inverter No. 5 1000W Inverter 2000W or 3000W Inverter Part Description ON/OFF/REM Switch Turns inverter ON, OFF, or REMOTE. 115V AC 60 Hz: 6 AC Outlets z Up to 15 A for 2000W and 3000W models z Up to 8.7 A for 1000W models z Up to 6.1 A for 700W models 7 USB Power Port Supplies 5V/2.1 A for charging tablets, smartphones, and other small appliances. 8 Remote Control Terminal Connects to the Wired Remote Control. 1 DC Side View No. 2 3 4 Part No.
Product Overview 700W Inverter 1000W Inverter 2000W or 3000W Inverter 2000W or 3000W Inverter 1 2 3 4 5 N AC Side View No. 8 7 Part G L 6 Description 1 ON/OFF/REM Switch Turns inverter ON, OFF, or REMOTE. 2 Power LED (Green) Indicates the operation status of the inverter. 3 GFCI LED (Yellow) Indicates that the ground fault circuit has been interrupted. In such case, restart the inverter.
Product Overview 700W Inverter No. 1000W Inverter 2000W or 3000W Inverter Part Description Connect to 115V AC devices operating at higher than 15 A or distributed wiring with multiple AC outlets. High Output AC Terminals 5 Remove the two screws on the protective cover to access the terminals. Terminal layout (facing the front panel) z Left: Neutral (N) z Middle: Ground (G) z Right: Live (L) Note that Neutral and Ground are bonded inside.
Wiring Diagram 700W Inverter 1000W Inverter 2000W or 3000W Inverter Wiring Diagram 700W Inverter ▇ AC Side View Wired Remote Control ON Loads (USB) AC Loads ERR RMS-P2 Remote control 12 USB AC
Wiring Diagram 700W Inverter ▇ 1000W Inverter 2000W or 3000W Inverter DC Side View Ground Battery - + + Battery Fuse Positive (DC) Negative (DC) Ground 13
Wiring Diagram 700W Inverter 1000W Inverter 2000W or 3000W Inverter 1000W Inverter ▇ AC Side View AC Loads Wired Remote Control Sub-panel (optional) ON Loads (USB) AC Loads ERR RMS-P2 N 14 G L Live wire (AC) Remote control Neutral wire (AC) USB Ground AC
Wiring Diagram 700W Inverter ▇ 1000W Inverter 2000W or 3000W Inverter DC Side View Ground Battery - + + Battery Fuse Positive (DC) Negative (DC) Ground 15
Wiring Diagram 700W Inverter 1000W Inverter 2000W or 3000W Inverter 2000W or 3000W Inverter ▇ AC Side View Wired Remote Control ON Loads (USB) AC Loads Sub-panel (optional) AC Loads ERR RMS-P2 N 16 G L Live wire (AC) Remote control Neutral wire (AC) USB Ground AC
Wiring Diagram 700W Inverter ▇ 1000W Inverter 2000W or 3000W Inverter DC Side View Ground Battery - + + Battery Fuse Positive (DC) Negative (DC) Ground 17
Installation Plan an Installation Site Size a Battery Bank Ground DC Wiring AC Wiring Installation CAUTION z Do not over-torque or overtighten the terminals. This could potentially damage the unit. z Refer to the technical specifications for maximum wire sizes on the controller and for the maximum amperage going through wires. WARNING z Ensure the inverter is in the OFF position before connecting to anything.
Installation Plan an Installation Site Size a Battery Bank Ground DC Wiring AC Wiring Size a Battery Bank Battery types and capacity relate to the overall inverter performance. To size a proper battery bank, you need to identify the loads that you will be utilizing, as well as an estimate duration (hours/day) you will be using the load. The inverter is only compatible with 12V battery banks and oversizing should be considered due to efficiency losses. 1.
Installation Plan an Installation Site Size a Battery Bank Ground DC Wiring AC Wiring Ground If available, the chassis ground lug should be connected to a ground point such as a vehicle chassis or boat grounding system. In fixed locations, connect the ground lug to earth ground. The connections to ground must be tight and against bare metal. Grounding is highly recommended for both when using the inverter in a mobile application, such as an RV, or in a building.
Installation Plan an Installation Site Size a Battery Bank Ground DC Wiring AC Wiring 2. On the DC side, remove the protection cap. 1.1.2 3. Unscrew Positive and Negative DC Input Terminals, connect a battery bank to the terminals, and tight the terminal screws. Torque: 14(±0.5) N·m 1.1.3 For your safety, it is recommended to use a battery fuse.
Installation Plan an Installation Site Size a Battery Bank Ground DC Wiring AC Wiring AC Wiring You can plug your AC loads directly into the receptacles on the inverter’s AC side. 1.2.1 I/ON N O/OFF N You can also permanently connect the AC output from the AC hardwire terminal through the AC knockout into a load sub-panel or additional AC outlets powered by the 1000W/2000W/3000W inverter. From left to right, the terminal block indicates: G N G Live/Hot (L), Neutral (N), and Ground (G).
Installation Plan an Installation Site Size a Battery Bank Ground DC Wiring AC Wiring Tested GFCI Models Manufacturer Model Number Leviton GFNT2 Hubbell GFP1305 Hubbell GF15WLA WARNING z Risk of electrical shock. Use only ground-fault circuit interrupters [receptacle(s) or circuit breaker(s)] compatible with your inverter. CAUTION z GFCIs shall be installed in a recreational vehicle’s wiring system to protect all branch circuits.
Operation Operations on Inverter Wired Remote Control Operation Operations on Inverter After proper battery and AC load connections, you can operate the inverter. 1. On the AC side, rock the ON/OFF Switch to the ON position. 2. The inverter is operating normally. 3. When finishing using the inverter, power off the AC loads first, and then rock the ON/OFF Switch to the OFF position. CAUTION z When the inverter turns on, it is normal to hear the fans run for a second and hear a beep.
LED Overview LED Overview LED Status Fault LED in solid red Alarm Long steady beeping sound Protection & Alarm Overtemperature protection No output from the inverter. Undervoltage shutdown No output from the inverter. Overload protection No output from the inverter output side. After 5s, the inverter automatically restarts. After five times of failed restart, the inverter needs to be restored by manually turning it on. No sound Short circuit protection No output from the inverter output side.
Troubleshooting Troubleshooting Indicator & Alarm Alarm beeps Fault LED lit, long beeping alarm sound, and inverter shutdown Potential Issue Input voltage is below 11V. Keep input voltage above 11V. Input voltage is above 16.0V. Keep input voltage below 16.0V. Input voltage is below 10V. Keep input voltage above 10V. Input voltage is above 16.5V. Keep input voltage below 16.5V. Allow inverter to cool down. Inverter overheats Check for adequate ventilation. Reduce the load on the inverter.
Dimensions 700W Inverter 1000W Inverter 2000W Inverter 3000W Inverter Dimensions CAUTION z Dimension tolerance: ±0.2 in (0.5 mm) 700W Inverter 12.2in [310mm] 5.8in [148mm] 7.4in [188mm] 3.3in [84mm] 700W 1000W Inverter 12.9in [328mm] 5.8in [148mm] 3.3in [84mm] N G L 6.
Dimensions 700W Inverter 1000W Inverter 2000W Inverter 3000W Inverter 2000W Inverter 17.8in [451mm] 9.8in [248mm] 8.6in [218mm] 4.0in [102mm] 2000W N G L 3000W Inverter 18.9in [480mm] 9.8in [248mm] 9.0in [229mm] 4.
Specifications General Data Electrical Data Wired Remote Data Specifications General Data Model RNG-INVT-70012V-P2 Output Waveform AC Terminals RNG-INVT-1000- RNG-INVT-2000- RNG-INVT-300012V-P2 12V-P2 12V-P2 Pure Sine Wave 2 x AC Sockets 2 x AC Sockets + Terminal Block 3 x AC Sockets + Terminal Block DC Terminals M8 - 1.
Specifications General Data Electrical Data Battery Input Voltage Range Maximum Continuous Battery Output Current Wired Remote Data 10V to 16V DC 58.3A 83.3A Inverter Efficiency >90% Full Load Efficiency >85% Power Consumption <10W <12W 166.6A 250A <24W <30W Battery Overoltage Shutdown 16.5V (±0.3V) DC Battery Low Voltage Alarm 11V (±0.3V) DC Battery Low Voltage Shutdown 10.5V (±0.3V) DC Wired Remote Data 30 Front Plate Dimensions 3.6 x 2.02 x 1.4 in / 92.2 x 51.2 x 35.
Technical Support Technical Support For additional support, contact the Renogy technical support team through renogy.com/ contact-us. Have the following information available when contacting Renogy. z Owner name z Contact information z Order number z Purchase channel z Serial number z Brief description of the issue Renogy offers premium services worldwide: North America US www.renogy.com CA ca.renogy.com AU au.renogy.com CN www.renogy.cn JP renogy.jp KR kr.renogy.com UK uk.renogy.
Renogy Empowered Renogy aims to empower people around the world through education and distribution of DIYfriendly renewable energy solutions. We intend to be a driving force for sustainable living and energy independence. In support of this effort, our range of solar products makes it possible for you to minimize your carbon footprint by reducing the need for grid power. Live Sustainably with Renogy Did you know? In a given month, a 1KW solar energy system will...
RENOGY.COM Visit renogy.com to find relevant documentation or get more support via "Contact Us". Renogy reserves the right to change the contents of this manual without notice. Join the Renogy Power Plus Community by downloading the DC Home App. Find your e-warranty here, and more.