Full Product Manual
Battery GEL  SEALED FLOODED  LI (LFP) USER
High Voltage 
Disconnect
16 V 16 V 16 V 16 V
Equalization 
Voltage
----- -----
14.6 V
Boost Voltage
Float Voltage 13.8 V 13.8 V 13.8 V -----
Boost Return 
Voltage
13.2 V 13.2 V 13.2 V 13.2 V
Low Voltage 
Reconnect
12.6 V 12.6 V 12.6 V 12.6 V
Under Voltage 
Warning
12 V 12 V 12 V 12 V
Low Voltage 
Disconnect
Equalization 
Duration
2 hours 2 hours
Battery Charging Parameters 
Voltage
Discharging Limit 
Boost Duration
2 hours 2 hours 2 hours -----
----------
9-17 V
9-17 V
9-17 V
9-17 V
0-10 Hrs.
1-10 Hrs.
9-17 V
9-17 V
9-17 V
9-17 V
9-17 V14.8V 
14.4 V14.6 V 14.4 V 14.2 V 
11.0V 11.0V 11.0V 11.0V
10.6 V  10.6 V  10.6 V  10.6 V 
*Battery  charging  parameters  in  LI mode and USER mode can be  programmed  using  the 
Solar Monitoring Software or Renogy BT App.
This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  class  B  digital 
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there is 
no guarantee that interference will not occur in a particular installation. If this equipment does 
cause  harmful  interference  to  radio  or  television  reception,  which  can  be  determined  by 
turning the equipment off and on, the user is encouraged to try to correct the interference by 
one or more of the following measures:
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause undesired operation.
**Default  charging  parameters  in  LI  mode  are  programmed  for  12.8V  LFP  battery.  Before 
using  Rover  to  charge  other  types  of  lithium  battery,  set  the  parameters  according  to  the 
suggestions from battery manufacturer.
***Parameters are multiplied by 2 for 24V systems.