Full Product Manual
Load Mode Options 
1 2 3 4
Programming Load Terminal
1. This screen is displaying the current Load Mode.
2. To enter screen 2 press and hold t
he Enter button. This screen will allow you to change
 the load mode. 
3. To change the load mode press the up or down button. 
4. 
Once you have selected the desired load mode press the Enter button to save the setting. 
5. To exit the programming setting press the left button. 
Setting Mode Description
0 Automatic(On/Off)
Time control
15 Manual 
16 Test
17
24Hr
The load will turn on at night when the solar 
panel is no longer producing any power after 
a  short  time  delay.  The  load  will  turn  off 
when the panel starts producing power.  
When the panel is no longer producing power 
the load will be ON for 1-14 hours or until the 
panel starts producing power. 
Used to troubleshoot  load terminal  (No 
Time Delay).  When voltage is  detected 
load  will  be  off  and  when  no  voltage  is 
detected load will be on. 
In this mode, the user can turn the Load 
On/Off  by  pressing  the  Enter  button  at 
any time.  
The load will be on for 24 hours a day.  
1-14 