System Status Troubleshooting
PV indicator Troubleshoot
BATT Indicator Troubleshoot
Load Indicator Troubleshoot
Error Indicator Troubleshoot
Off during daylight
Using a multimeter check the battery voltage and verify it is not
exceeding 32 volts.
Disconnect loads, if any, and let the PV modules charge the battery
bank. Use a multi-meter to frequently check on any change in battery
voltage to see if condition improves. This should ensure a fast charge.
Otherwise, monitor the system and check to see if system improves.
The Load circuit on the controller is being shorted or
overloaded. Please ensure the device is properly connected to
the controller and make sure it does not exceed 20A (DC).
White Slow Flashing
White Fast Flashing
White Fast Flashing
WhiteSolid System Error. Please check LCD for Error code
Ensure that the PV wires are correctly and tightly secured inside
the charge controller PV terminals. Use a multi-meter to make
sure the poles are correctly connected to the charge controller.
Error Codes
E0
E1
E2
E3
E4 Load short circuit
E5 Load overloaded
E6
E8
E10
Error Number Description
PV over-voltage
PV input over-current
Controller over-temperature
Battery over-voltage
Battery over-discharged
No error detected
Battery under-voltage