Full Product Manual
21 
System Status Troubleshooting 
PV indicator 
Troubleshoot 
Off during 
daylight 
Ensure that the PV wires are correctly and tightly secured inside the 
charge controller PV terminals. Use a multi-meter to make sure the 
poles are correctly connected to the charge controller. 
BATT Indicator 
Troubleshoot 
White Slow 
Flashing 
Disconnect loads, if any, and let the PV modules charge the battery 
bank. Use a multi-meter to frequently check on any change in battery 
voltage  to  see if condition  improves.  This  should ensure  a  fast 
charge. Otherwise, monitor the system and check to see if system 
improves. 
White Fast 
Flashing 
Using  a  multimeter  check  the  battery  voltage  and  verify  it  is  not 
exceeding 32 volts. 
Load Indicator 
Troubleshoot 
White Fast 
Flashing 
The Load circuit on the controller is being shorted or overloaded. 
Please ensure the device is properly connected to the controller and 
make sure it does not exceed 20A (DC). 
Error Indicator 
Troubleshoot 
White Solid 
System Error. Please check LCD for Error code 
Error Codes 
Error Number 
Description 
E0 
No error detected 
E1 
Battery over-discharged 
E2 
Battery over-voltage 
E3 
Battery under-voltage 
E4 
Load short circuit 
E5 
Load overloaded 
E6 
Controller over-temperature 
E8 
PV input over-current 
E10 
PV over-voltage 
E13 
PV reverse polarity 