Full Product Manual
Battery Safety 
Use only sealed lead-acid, flooded, gel or lithium batteries which 
must be deep cycle.
Explosive  battery  gases  may  be  present  while  charging.  Be  certain  there  is  enough 
ventilation to release the gases. 
Be careful when working with large lead acid batteries. Wear eye protection and have 
fresh water available in case there is contact with the battery acid.
Over-charging  and  excessive  gas  precipitation  may  damage  the  battery  plates  and 
activate material shedding on them. Too high of an equalizing charge or too long of one 
may cause  damage.  Please carefully  review  the specific  requirements of the battery 
used in the system.
Equalization  is  carried  out  only  for  non-sealed  /  vented/  flooded  /  wet  cell  lead  acid 
batteries.
Do 
NOT 
equalize VRLA type AGM / Gel / Lithium cell batteries UNLESS permitted by 
battery manufacturer.
Default charging parameters in  Li mode  are programmed for 12.8V Lithium  Iron 
Phosphate  (LFP)  Battery  only.  Before  using  Rover  to  charge  other  types  of  lithium 
battery, set the parameters according to the suggestions from battery manufacturer.
Carefully read battery manuals before operation.
Do 
NOT
 let the positive (+) and negative (-) terminals of the battery touch each other.
Connect  battery  terminals  to  the  charge  controller  BEFORE  connecting 
the solar panel(s) to the charge controller. NEVER connect solar panels to 
charge controller until the battery is connected. 
Do NOT connect any inverters or battery charger into the load terminal of 
the charge controller.
Once equalization is active in the battery charging, it will not exit this stage 
unless  there  is  adequate  charging  current  from  the  solar  panel.  There 
should be NO load on the batteries when in equalization charging stage. 
Recycle battery when it is replaced. 